7. Diagnostics
There are several ways you can check on the status and availability of GW21W.
7.1 Use Standard TCP/IP Utility
ping
Command
From Windows
Start
menu, select
Run
and type in “
ping <TCP Server IP address>
”.
If the connection is established, the Reply messages are displayed, otherwise it will indicate Request
timed out.
7.2 Use monitor.exe Configuration Utility Program
Use monitor.exe configuration program that comes with the product CD or diskette to check on the status
of GW21W. The status can be read from “
AP version
” column of the tool.
Status
Descriptions
S
The system is configured as a TCP Server and not yet connected.
C
The system is configured as a TCP Client and not yet connected.
U
The system is configured as an UDP.
A
The TCP Server and is connected.
B
The TCP Client and is connected.