9
MAINTENANCE & SERVICE
Proper maintenance ensures that your
generator will continue to operate safely
and efficiently. Improper maintenance may
cause the generator to malfunction and can
lead to damage to connected appliances or to
generator components.
Shut off the engine before performing
any maintenance. Allow engine to cool
down completely before performing any
maintenance tasks. Maintenance should be
performed in a well-ventilated area.
It is recommended that some of the
maintenance procedures outlined in this
section should be performed by an authorised
dealer or qualified technician.
In order to maintain good performance
and extend the life of this generator,
periodic inspection and adjustments should
be performed based on the following
maintenance schedule.
GENERAL MAINTENANCE
• Check for leaks around the fuel tank,
fuel hose, fuel tap and carburettor.
• Check for exhaust leaks while the engine
is running. Leaks should be repaired before
continuing operation of the generator.
• Check the engine oil level daily
- add oil as necessary.
ITEM
TASK
DAILY
EVERY 20
HOURS
EVERY 50
HOURS
EVERY 100
HOURS
EVERY 300
HOURS
General Inspection
Engine Oil*
Check oil level
Replace
Air Filter
Inspect
Clean
Fuel Tap
Sediment
Bowl
Cleaning
Spark Plug/
Spark
Arrestor
Inspect and clean
Replace
Valve
Clearance
Inspect and adjust
Combustion
Chamber
Inspect and clean
Fuel Tank
and Strainer
Clean
Inline Fuel
Filter
Inspect
Replace
Fuel Line
Inspect
Inspect every two months regardless of use. Replace if necessary.
*
Note: it is recommended to replace the engine oil after the first 10 hours of operation and then every 50 hours.
JAM2013_atomic_TP_manual_ED3.indd 9
11/05/12 3:45 PM