Atom InfaLite Operation Manual Download Page 1

Equipment for neonatal and premature infants/LED Examination Light

Atom InfaLite

Operation Manual

TO THE OPERATOR AND THE PERSON IN CHARGE OF 

MAINTENANCE AND CARE OF THE UNIT:

Read this 

 

Manual

 carefully before operating the unit.

Keep this 

 

Manual

 where it is readily accessible for reference when needed.

This Manual contains description of all the functions available. Please skip 

 

any section unrelated to your unit.

ORIGINAL

Summary of Contents for InfaLite

Page 1: ...OR AND THE PERSON IN CHARGE OF MAINTENANCE AND CARE OF THE UNIT Read this Manual carefully before operating the unit Keep this Manual where it is readily accessible for reference when needed This Manu...

Page 2: ...Via Libia 54 20081 Abbiategrasso MI Italy Tel 39 02 9466329 Fax 39 02 9081428 EU OFFICE...

Page 3: ...th applicable waste disposal laws and regulations Federal US and Canada Law restricts this device to sale by or on the order of a physician CAUTION INTENDED USE The unit utilizes quality medical white...

Page 4: ...GER WARNING CAUTION Definition of Symbols 1 Symbols to indicate danger warning or caution Symbol Title and indication General attention Indicates unspecified general danger warning or caution 2 Symbol...

Page 5: ...the European Community WEEE symbol In the EC area an electrical and electronic product falling in one of the categories specified by DIRECTIVE 2002 96 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL...

Page 6: ...are of Equipment It is the user a hospital a doctor s office a clinic that is responsible for the operation maintenance and care of the electric equipment for medical use The equipment should be used...

Page 7: ...nstallation 13 3 4 Daily Inspection 14 OPERATION 4 How to Operate the Unit 15 4 1 Operating the Irradiation Head 15 4 2 Lighting and Light Control 17 4 3 Turning Off and Storing the Light 17 MAINTENAN...

Page 8: ...care of the usage environment Using the unit in a strong electromagnetic environment may affect the light intensity Do not use the unit next to other devices Using the unit next to or stacked with oth...

Page 9: ...tric shock Do not expose the unit to extraordinarily high temperature or excessive humidity Do not let the unit hit anything fall or drop inadvertently Do not forcefully bend the flexing arm When adju...

Page 10: ...2 Main Unit 2 1 No Name Irradiation head Operation panel Flexing arm Arm joint Linking arm Arm cover Mounting section Relay cable Cable cover AC adapter AC adapter plug F Rail Attachment sold separate...

Page 11: ...tification Irradiation Head 2 2 No Name Non contact sensor White LED with lens Lens cover Irradiation head cover Operation Panel 2 3 No Name Operation indicator Light control button Light control butt...

Page 12: ...Power Outlet 3 2 The electrical rating of this unit is as follows AC120 240V power consumption 13VA frequency 50 60Hz operating voltage range AC120 240V 10 Do not connect the unit to any other power...

Page 13: ...pplied with the unit AU US UK EU Attaching a plug to the power adapter Align the plug with the groove of the power adaptor Slide the plug in the direction of the arrow until the lock button clicks Rem...

Page 14: ...outlet The stand by indicator on the irradiation head will turn green CAUTION Keep an area of over 15cm around the power outlet clear so that the AC adapter can be quickly removed The stand by indica...

Page 15: ...Tighten the fixing knob Make sure that the placement of the mounting section does not interfere with the operation of the incubator or the treatment of the infant Make sure that the F Rail Attachment...

Page 16: ...carefully for any faults contamina tion missing parts or defective parts to make sure that it can be operated safely Be sure to inspect the unit at the start of each day Operating the unit without ins...

Page 17: ...diation unit will overheat and cause the unit to break down Make sure that the Dual Incu i canopy does not hit anything when raising and lowering it Before moving the canopy of the Dual Incu i upward...

Page 18: ...hat the hood of the incubator and irradiation head of this unit are slightly angled so that they do not become perpendicular If they are perpendicular the non contact sensor may become unresponsive Ve...

Page 19: ...ds when an object is within 15cm of the irradiation head Operation indicator is blue Irradiation head Within approx 15cm Operation panel 3 When adjusting the light press the light control button or to...

Page 20: ...ation If contamination is suspected while the unit is in operation stop using it immediately and disinfect it The timing and method of disinfection varies with the frequency and conditions of use The...

Page 21: ...ur local Atom representative annually for periodical inspection Parts requiring periodical replacement Some parts need to be replaced periodically depending on their period of use Measuring the Light...

Page 22: ...Cable cover The F Rail Attachment Pole Mounting Attachment should not be broken Otherwise the unit may not receive power Stand by switch Pressing the stand by switch and activating the non contact se...

Page 23: ...hite LED should emit light Flexing arm Move the main unit The irradiation head should hold in place It may not be secure while in a horizontal position and may drop downward but this is not a defect L...

Page 24: ...the plug may cause mal functions during operation AC adapter 2 3 years Damage or dirt on the cord may cause malfunctions during operation Flexing arm 2 3 years Deterioration or damage of the flexing...

Page 25: ...sity to change YES NO Is the lens cover free of any cracks dirt or damage YES NO Is the flexing arm free of damage Is the irradiation head held in place YES NO Is the linking arm free of damage Do the...

Page 26: ...tion Disposal 6 7 The medical institution concerned is responsible for proper disposal of the unit old parts past their expected life span and disposables in accordance with applicable waste disposal...

Page 27: ...button The light does not turn on Did you move your hands near the non contact sensor Is the palm of your hand outside of the detection zone for the non contact sensor approx 15cm Is the lens cover d...

Page 28: ...adiation head and the light intensity measurement device is 60cm Light field life 10 000 hours lumen maintenance factor 70 Non contact sensor Responds to objects within approximately 15cm Dimensions 5...

Page 29: ...it is intended for use in the electromagnetic environment specified below The customer or the user of the unit should assure that it is used in such an environment Emissions test Compliance Conducted...

Page 30: ...ground port Surges IEC61000 4 5 0 5kV 1kV Line to line Voltage dips Voltage interruptions IEC61000 4 11 0 Ut 0 5cycle 0 45 90 135 180 225 270 315 0 Ut 1cycle single phase 0 70 Ut 25 30cycle single ph...

Page 31: ...oximity fields from RF wireless communications equipment Test frequency MHz Maximum power W Distance m Immunity test level V m 385 1 8 0 3 27 450 2 0 3 28 710 0 2 0 3 9 745 780 810 2 0 3 28 870 930 17...

Page 32: ......

Page 33: ......

Page 34: ......

Page 35: ...rictly prohibited The contents of this Manual are subject to change without notice due to technical improvement All possible measures have been taken to ensure the accuracy of the contents of this Man...

Page 36: ...18 15 Hongo 3 chome Bunkyo ku Tokyo Japan Tel 81 3 38152311 Fax 81 3 38123144 C73MC013 201910...

Reviews: