CHAPTER 1 FEATURES AND SPECIFICATION

1. Features

Enclosure:

Seamless steel pipe extruded for maximum protection.

Multi-weighing units

:

Kg, lb, N are selectable, generally kg are default unit.

Multi-function operation:

Tare

Zero

Auto zero tracking

Total

Hold

Overload warning and record, Calibration through

remote controller, etc functions.

User-friendly design:

Large red 5 digit LED display (digit height 45mm); Gravity compensation; Safety factor up to 4 times
capacity; Battery Operated with low battery indication; Automatic turn off , power-saving function.

2. Main technical data

Standard

According to OIML class III

Display

45mm (1.8’’) 5digits LED

Zero Range

4% F.S.

Tare Range

100% F.S.

Stable Time

≤10 seconds

Overload Indication

100% F.S. + 9e

Max. Safety Load

125% F.S.

Ultimate Load

400% F.S.

Battery Life

≥70 hours

Battery Type

Fully sealed Lead-Acid battery, 6V/7Ah

Adapter

DC9V/1000mA

Nominal operating Temp.

- 10

~ + 40

Operating Humidity

≤85% RH under 20

Remote Controller Distance

Min. 15m

Battery of Remote Controller AAA Size battery, 1.5V

2

Digital Crane Scale

3

Automation       www.ato.com      [email protected]     Global Shipping      +1 800-585-1519 (Toll-free)

Summary of Contents for GSP911-30

Page 1: ...DIGITAL CRANE SCALE USER MANUAL SKU ATO CRS 50T Digital Crane Scale Automation www ato com sales ato com Global Shipping 1 800 585 1519 Toll free...

Page 2: ...ontrol 5 CHAPTER 3 OPERATION GUIDE 6 1 Turn on off 6 2 Zero 7 3 Tare 7 4 Hold 7 5 Accumulation 7 6 Accumulation Search 7 7 Accumulation Clear 8 8 Battery Voltage 8 9 Brightness 8 10 Zero Point 8 11 Un...

Page 3: ...ery every three months to preserve the life span of the battery and recharge it before operation 5 The battery charger is included in the scale package Please use this charger It s normal that the cha...

Page 4: ...Battery Operated with low battery indication Automatic turn off power saving function 2 Main technical data Standard According to OIML class III Display 45mm 1 8 5digits LED Zero Range 4 F S Tare Ran...

Page 5: ...it can be used for about 70hours Low battery warning When the digits flash it means the battery needs to be recharged The scale will power off automatically after 1 to 2 hours operation if the batter...

Page 6: ...2 Put the goods into container the scale will display goods net weight 3 If move goods and container the scale will display minus value of tare weight 4 REMOTE CONTROLLER Press any key on the remote...

Page 7: ...ightness of LED 7 F2 Function Key used with F1 together 8 HOLD It used for hold function details see Chapter3 4 9 OFF Turn off the crane scale CHAPTER 3 OPERATION GUIDE express key on remote controlle...

Page 8: ...n goods it will display net weight of goods 4 HOLD OPERATION ILLUSTRATION Press HOLD Hold the weight reading no matter load change Press HOLD again Return to normal weighing status 5 ACCUMULATION OPER...

Page 9: ...should be between 5 8 and 6 9 if below than 5 8 the digits flash you need to recharge immediately 9 BRIGHTNESS OPERATION ILLUSTRATION F1 1 5 total 5 options from darkness to brightness Default is 3 1...

Page 10: ...take cap 30000kg as example choose FS 30 Press TARE confirm Id 05 New scale the screen display Id 05 if scale calibrated the screen display calibrated division Press ZERO or CLEAR to choose Id 10 Choo...

Page 11: ...if scale calibrated the screen display calibrated value Press ZERO or CLEAR to choose OFF 2 Choose turn off method 0 2 total 3 options 0 turn off by hand 1 if no operation the screen display after 15...

Page 12: ...g 20000kg Second load must exceed Load 1 20 capacity Waiting until STB light on Press SHIFT 16000 Mention you Load2 must exceed 16000kg Press TARE ZERO CLEAR 20000 Input actual weight 20000kg waiting...

Page 13: ...t be negative Waiting Err10 Weight less than Min Capacity Can t accumulate the value Err11 Accumulated times overflow Can t accumulate after 30times Err12 Accumulated weight overflow Can t accumulate...

Page 14: ...or PCB Requires authorized service Load cell cable damaged Check and replace load cell Out of calibration Check calibration Display experiences excessive Zero drift between weighment Scale electronic...