3-12
to short circuit and become very hot.
(2) Packaging After Use.
(a) Remove battery cap and remove battery.
(b) Inspect the battery housing for corrosion or moisture. Clean
and dry if necessary.
(c) Replace the battery cap.
(d) Remove the demist shield or sacrificial window if installed.
Install objective lens cap.
NOTE
• Prior to placing OTS-X into carrying case, ensure OTS-X and
case are free of dirt, dust, and moisture.
3.2.5. INTERCHANGEABLE LENSES
The objective lens on the OTS-X unit can be interchanged. To
change lenses unscrew current lens counter clockwise and re-
move. Take desired lens and screw into body clockwise.
Interchangeable
14-mm Lens
FIGURE 3.12. INTERCHANGEABLE LENSES
50-mm Lens
70-mm Lens
30-mm Lens