Before getting started make sure to follow these steps:
• Install the battery into its housing with the polarity order 

shown on the main body of the unit. The CR123A battery 

used with  adapter. Install adapter first, then CR123A .  AA 

battery used without adapter.
• Switch on the scope with the protective lens cover still 

attached to the lens.
• Make sure that the green luminance of the light intensifier 

tube is present.
• Observe the scene, and adjust the diopter and/or lens for 

optimal image clarity.
• You may now enter a dark environment or simply shut the 

lights off in order to darken the room.
• Next, remove the lens cap/daylight filter.

opERATIng

mounTIng

1.  Mount the PS-22 with Adapter onto the A.R.M.S.#10 or A.R.M.S.#19 ACOG with 2 screws M5x8.
2. Unscrew the protective back cap from PS-22.
3. Screw the Light Screen into the thread in back side of unit.
4. Slightly loosen the fixing screws or levers of mount.
5. Place the PS-22 on the weaver rail of the fire arm before objective of daytime scope on the 

minimal distance from it. The optical axes of PS-22 and daytime scope must have diver-

mARs X4

2nd, 2nd+, 3rd, 4th 

F1:1.5

4X

9 deg.

10 m to 

45mm

7mm

-6/+2

120MOA

1/4MOA

one 3V (CR123A) or 1.5V (AA)

Super 450mW 

-51°C to +45°C

55 (3V)/ 40 (1.5V )hours

20m for 1 hour

Red or Amber On Green

235x90x95mm

1.3kg 

 

 

 

                

Generation ............................. 
Lens of system  ..........................
Magnification ..........................
FOV ..........................................
Range of focus  .........................
Eye relif .....................................
Exit pupil ...................................
Diopter adjustment ...............
Windage & elevation  ................
Adjustment step size ..............
Power supply ........................
IR illuminator ............................ 
Operating temperature .......
Battery life................................
Waterproof ...............................

Reticle ....................................

Dimensions .............................
Weight .................................... 

mARs X6

2nd, 2nd+, 3rd, 4th 

F1:2.0

6X

6 deg.

25 m to 

45mm

7mm

-6/+2

80MOA

1/6MOA

one 3V (CR123A) or 1.5V (AA)

Super 450mW 

-51°C to +45°C

55 (3V)/ 40 (1.5V )hours

20m for 1 hour

Red or Amber On Green

295x95x100mm

1.55 kg 

Battery cap

Battery cap

AA  

battery

CR123A 

battery

Battery 

adapter

Summary of Contents for ATN MArs x4

Page 1: ...mmerce It is unlawful and strictly prohibited to export or attempt to export or otherwise transfer or sell any hardware or technical data or furnish any service to any foreign person whether abroad or...

Page 2: ...d to achieve optimum performance Operation switch F1 1 5 lens Elevation Windage 6 2 Diopter Battery housing Mounting system IR brightness adjustment Digital Infra Red Illuminator Battery housing Fixat...

Page 3: ...from PS 22 3 Screw the Light Screen into the thread in back side of unit 4 Slightly loosen the fixing screws or levers of mount 5 Place the PS 22 on the weaver rail of the fire arm before objective of...

Page 4: ...for viewing objects at different distances automatic brightness control System The device has a built in Automatic brightness control This control automatically adjusts the brightness of Image Intens...

Page 5: ...lor and 5 degrees of brightnes of illumination for each color The knob of brightnes ajustment reticle and color select is located on the top of the boby of the scope On the knob there are marking with...

Page 6: ...s unit was compiled in a controlled environment If you use the rubber eyecaps for a long period of time you may suffer skin inflammation If you develop any symptoms consult a doctor immediately TROUBL...

Page 7: ...not be liable for any claims actions suits proceedings costs expenses damages or liabilities arising out of the use of this product Operation and use of the product are the sole responsibility of the...

Page 8: ...den Ave Suite 1B South San Francisco CA 94080 phone 800 910 2862 650 875 0130 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free...

Reviews: