120
8126F–AVR–05/12
ATtiny13A
18.5
System and Reset Characteristics
Note:
1. When RESET pin used as reset (not as I/O).
2. Not tested in production.
18.5.1
Enhanced Power-On Reset
Note:
1. Values are guidelines only.
2. Threshold where device is released from reset when voltage is rising.
3. The Power-on Reset will not work unless the supply voltage has been below V
POA
.
18.5.2
Brown-Out Detection
Note:
1. V
BOT
may be below nominal minimum operating voltage for some devices. For devices where
this is the case, the device is tested down to V
CC
= V
BOT
during the production test. This guar-
antees that a Brown-out Reset will occur before V
CC
drops to a voltage where correct
operation of the microcontroller is no longer guaranteed.
Table 18-4.
Reset, Brown-out, and Internal Voltage Characteristics
Symbol
Parameter
Condition
Min
Typ
Max
Units
V
RST
RESET Pin Threshold
Voltage
0.2 V
CC
0.9V
CC
V
t
RST
Minimum pulse width on
RESET Pin
V
CC
= 1.8V
V
CC
= 3V
V
CC
= 5V
2000
700
400
2500
2500
2500
ns
V
HYST
Brown-out Detector
Hysteresis
50
mV
t
BOD
Min Pulse Width on
Brown-out Reset
2
µs
V
BG
Internal bandgap reference
voltage
V
CC
= 5V
T
A
= 25°C
1.0
1.1
1.2
V
t
BG
Internal bandgap reference
start-up time
V
CC
= 5V
T
A
= 25°C
40
70
µs
I
BG
Internal bandgap reference
current consumption
V
CC
= 5V
T
A
= 25°C
15
µA
Table 18-5.
Characteristics of Enhanced Power-On Reset. T
A
= -40 to +85
°
C
Symbol
Parameter
Min
Typ
Max
Units
V
POR
Release threshold of power-on reset
1.1
1.4
1.6
V
V
POA
Activation threshold of power-on reset
0.6
1.3
1.6
V
SR
ON
Power-On Slope Rate
0.01
V/ms
Table 18-6.
V
BOT
vs. BODLEVEL Fuse Coding
BODLEVEL[1:0] Fuses
Min
Typ
Units
11
BOD Disabled
10
1.7
1.8
2.0
V
01
2.5
2.7
2.9
00
4.1
4.3
4.5