Testing the ATSTK94

2449A–FPSLI–01/02

Downloading to the
Configurator

Go to the

Start

menu and choose

Programs > Atmel > Atmel CPS 7.0x

. Atmel

CPS opens, see Figure 1.

Figure 1.

Atmel CPS Window

Select

/P Partition, Program and Verify from an Atmel File

from the

Procedure

pull-down menu in the CPS window.

Use the

button from the

Input File

pull-down menu to locate the

test_fpslic.bst

file under

c:\training\fpslic\lab1

.

Use the

button from the

Output File

pull-down menu to indicate the

out.bst

file

under

c:\training\fpslic\lab1

.

Select

1M

from the

EEPROM Density

pull-down menu.

Use the default options for the rest.

Press

Start Procedure

to program the Configurator.

If the utility has not been calibrated on a given PC, the Clock Calibration dialog will
be displayed when the

Start Procedure

button is clicked, see Figure 2. For best

results, it is highly recommended to allow

Clock Calibration

to proceed prior to the

execution of the procedure. The clock calibration routine accounts for any variations
in time delay units between different processors.

Summary of Contents for ATSTK94

Page 1: ...e supplied with the kit which per forms a board test It is recommended to perform the board test when you receive the kit to test both your connections to the board and the board itself Install System Designer from the CD please refer to the Installation Licensing and Troubleshooting tutorial available on the Atmel web site at http www atmel com atmel products prod319 htm Request and Configure you...

Page 2: ... button from the Output File pull down menu to indicate the out bst file under c training fpslic lab1 Select 1M from the EEPROM Density pull down menu Use the default options for the rest Press Start Procedure to program the Configurator If the utility has not been calibrated on a given PC the Clock Calibration dialog will be displayed when the Start Procedure button is clicked see Figure 2 For be...

Page 3: ...bration can be performed again or at a later time by going to the Calibrate menu and selecting Calibrate now The out bst file can be overwritten If successful the results are shown in Figure 3 Figure 3 CPS Window Results After CPS reports successful completion you can switch from Prog to Run Your design starts to run The Alphanumeric will show a count sequence from 0 to 9 and from A to Z and will ...

Page 4: ...d Prog Run in the wrong position or FATAL_ERROR CMD ack_sense timed out Double check the orientation of cable connected to evaluation board Any other failure would be related to the following Check to see that the Jumpers and Switches are in default positions see Table 1 The next area to check is the pinlocks In Figaro during the parts process make sure that you have selected to assign pinlocks Wi...

Page 5: ...the jumper is changed and it should be set on the inner side to connect to the 4 MHz crystal Connecting towards the outer side of the board will connect to the 18 MHz crystal JP18 Has a Jumper Connected JP19 Set to the RESET Position JP20 Jumper connects the SER_EN pin of the AT17 device to the PORTE pin 7 of the microcontroller By connecting this jumper you can perform 2 wire serial interface Def...

Page 6: ... TEL 1 408 436 4270 FAX 1 408 436 4314 Microcontrollers Atmel Corporate 2325 Orchard Parkway San Jose CA 95131 TEL 1 408 436 4270 FAX 1 408 436 4314 Atmel Nantes La Chantrerie BP 70602 44306 Nantes Cedex 3 France TEL 33 2 40 18 18 18 FAX 33 2 40 18 19 60 ASIC ASSP Smart Cards Atmel Rousset Zone Industrielle 13106 Rousset Cedex France TEL 33 4 42 53 60 00 FAX 33 4 42 53 60 01 Atmel Colorado Springs...

Reviews: