2. RS232

The Atlona switcher is featured with RS232 control port which allows users to control the switch though a control system 
or from the computer.

The serial communication parameters are 9600 baud rate, 8 bit, No Parity and 1 stop bit
When the unit recognizes a complete command it will perform the requested action - there is no delimiter character

required.

Note: The unit does not send out a feedback message when a value is changed from the front panel or by IR control. If
the switcher needs to be controlled though front panel in addition to the RS232 control, user should regularly verify the
unit’s status to ensure the control system accurately reflects the current settings.

3. RS-232 Commands

 

Baud Rate : 9600 bps
Data Bit :8 bits
Parity : None
Stop Bit :1 bit

• Each command is terminated with a Carriage Return
• Each feedback is terminated with a Carriage Return
• Code entry is CASE SENSITIVE.
• Do not insert spaces between letter/number code entries.

Command

Description

Feedback

PWON

Power ON

PWON

PWOFF

Power OFF

PWOFF

All#

Reset all input signals to matching output.

(Input 1 to Output 1, Input 2 to Output 2,etc…)

All#

x1AVx1

Switch specified input to the output. If input is 5, 
then command would be x5AVx1

x1AVx1

Status

Display input currently routed to the output

x3AVx1

Mreset

Reset device to manufacture default

Mreset

Note1:

 

Feedback for for a command repeats the original command. Example, if x1AVx1 is a command, the feedback

is the same and if the command is x2AVx1, the feedback would also be x2AVx1

Note2: 

If command fails, the feedback should be “Command FAILED”

Summary of Contents for AT-DVI-81A

Page 1: ...www atlona com Toll free 1 877 536 3976 Local 1 408 962 0515 8 x 1 DVI Switcher with Stereo Audio AT DVI 81A User Manual ...

Page 2: ...ifications 3 5 Panel Descriptions 3 5 1 Front Panel 3 5 2 Rear Panel 4 6 Remote Control 5 7 IR Extender 5 7 1 IR Extender Connection 5 7 2 IR Extender Package 6 8 RS232 6 8 1 RS 232 Serial Interface 6 8 2 RS232 7 8 3 RS232 Commands 7 9 Safety Information 8 10 Warranty 9 11 Atlona Product Registration 10 TABLE OF CONTENTS ...

Page 3: ...r Switcher is featured with 8 x Stereo audio inputs and 1 x Output Switcher is able to support high resolutions up to 1920x1200 WUXGA or 1080p 1920x1080 AT DVI 81A is fully HDCP compliant and therefore can also work with HDMI sources DVI HDMI adapters will be required High Bandwidth Support up to 6 75Gbps allows high motion video and high resolutions to be passed though with out any delay or degra...

Page 4: ... 6 75Gbps Infrared frequency 38 KHz Safety Approvals CE FCC RoHs 2002 95 EC Dimensions LWH 19 x 7 87 x 1 75 482mm x 200mm x 44mm 1U Power Supply DC12V 1 25A 110 240V Shipping Weight 5 80 lb SPECIFICATIONS 1 Front Panel PANEL DESCRIPTIONS 1 POWER ON SWITCH The power switch turns the unit ON and OFF The LED will illuminate red to indicate that the switcher is ON 2 INPUT SOURCES STATUS LED s Input so...

Page 5: ...ut allows user to connect an IR cable up to 1000ft to be able to control the unit from far away IR Extender Jack Female Jack inner OD 3 5 mm 1 8 inch 3 RS 232 CONNECTION RS 232 control port allows users to control AT DVI 81A though a 3rd party control system or though the computer directly Port Specifications DB 9pin Female connector 4 INPUTS 1 8 DVI and Stereo Audio Connect up to 8 x DVI with Ste...

Page 6: ...source with selection button 3 INPUT 3 Select input 3 source with selection button 4 INPUT 4 Select input 4 source with selection button 5 INPUT 5 Select input 5 source with selection button 6 INPUT 6 Select input 6 source with selection button 7 INPUT 7 Select input 7 source with selection button 8 INPUT 8 Select input 8 source with selection button REMOTE CONTROL IR EXTENDER 1 IR Extender Connec...

Page 7: ...age RS232 1 RS 232 Serial Interface RS 232 serial interface allows connecting a control system or a computer to it for controlling the switcher Pin RS 232 Definition 1 Not used 2 Tx Transmitter 3 Rx Receiver 4 Not used 5 GND Ground 6 Not used 7 Not used 8 Not used 9 Not used 1 5 6 9 ...

Page 8: ...ely reflects the current settings 3 RS 232 Commands Baud Rate 9600 bps Data Bit 8 bits Parity None Stop Bit 1 bit Each command is terminated with a Carriage Return Each feedback is terminated with a Carriage Return Code entry is CASE SENSITIVE Do not insert spaces between letter number code entries Command Description Feedback PWON Power ON PWON PWOFF Power OFF PWOFF All Reset all input signals to...

Page 9: ...occurs unplug the device and plug it back in Protect and route power cords so they will not be stepped on or pinched by anything placed on or against them Be especially careful of plug ins or cord exit points from this product Avoid excessive humidity sudden temperature changes or temperature extremes Keep this product away from wet locations such as bathtubs sinks laundries wet basements fish tan...

Page 10: ... or items on the product contact with fluids and physical misconduct i e kicking or punching Any replacement product will be warranted for the remainder of the original warranty period No other warranties To the maximum extent permitted by applicable law Atlona Technologies and its suppliers disclaim all other warranties either expressed or implied including but not limited to implied warranties o...

Page 11: ...if your product is lost or stolen and helps ensure you ll receive notification of performance issues and firmware updates At Atlona we respect and protect your privacy assuring you that your registration information is completely secure Atlona product registration is completely voluntary and failure to register will not diminish your limited warranty rights To register go to http www atlona com re...

Reviews: