background image

2

 Warning:

 TO REDUCE THE RISKS OF FIRE, ELECTRIC SHOCK OR INJURY TO 

PERSONS, OBSERVE THE FOLLOWING

2  High voltage and moving parts around motors and motor driven equipment can cause serious 

or fatal injuries. Always disconnect power source at main switch before wiring, servicing or 
cleaning unit. Do not rely on fan control device to prevent unexpected start-up or electrical 
shock. In addition, power supply must have fuses or circuit breakers for short circuit 
protection.

3  All electrical wiring must be performed by qualified persons in accordance and conform withal 

applicable national and local electrical codes.

4   Fan should be secure in its electrical grounding to avoid possible electrical shock.

5   Fan should not be used in any wet or hazardous location In addition, its ambient temperature 

should not exceed 40 degrees Celsius.

6   Power supply should conform to voltage rating of 220-240V~, 50/60Hz.

7  Before applying power, visually re-inspect the installation. Make sure that all guards and 

protective devices are securely in place and all visible screws and bolts are tightened. All 
set-screws must be retightened before installation.

8  

Warning:

 to reduce the risk of fire, electrical shock or personal injury, mount hanging bracket 

to outlet box marked "Acceptable for fan support and a hanging weight of 45 Lbs (20.4 Kgs)." 
Do not mount fan to sheet rock or drywall type materials and use only the screws provided 
with the outlet box.

9  This appliance is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been 
give supervision or instruction conceming use of the appliance by a person responsible for 
their safety.

10  Children should be supervised to ensure that they do not play with the appliance.

A. Use this unit only in the manner intended by the manufacturer. If you have any questions, 

contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at service panel and lock the service 

disconnecting means to prevent power from being switched on accidentally. When the 
service disconnecting means cannot be locked, securely fasten a prominent warning 
device, such as a tag, to the service panel.

C. Installation work and electrical wiring must be done by qualified persons in accordance 

with all applicable codes and standards including fire-related construction.  

D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other 

hidden utilities.

READ AND SAVE THESE SAFETY AND INSTALLATION 

INSTRUCTIONS.

Consult a licensed electrician if unsure of any point below mentioned.

DANGER/WARNING/CAUTION

Summary of Contents for Melody AC-MGM2

Page 1: ... use any electric or battery powered tools in the assembly and installation of this or any Matthews Fan Company product FAN RATING AC 220 240V 50 60Hz AC MGM2 READ AND SAVE THESE INSTRUCTIONS WALL MOUNTED FAN Melody ...

Page 2: ...py c Hanger bracket d Wall control with 2 mounting screws e Mounting plate f Allen wrench g Package hardware Mounting hardware wood screws 4 screws 2 lock washers 4 washers 4 star washers 4 Philips screw driver Standard flat head screw driver 11 mm wrench Step ladder Wire cutters a b c d e f g TOOLS AND MATERIALS REQUIRED ...

Page 3: ...ging bracket to outlet box marked Acceptable for fan support and a hanging weight of 45 Lbs 20 4 Kgs Do not mount fan to sheet rock or drywall type materials and use only the screws provided with the outlet box 9 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been give su...

Page 4: ... Installing the hanger bracket to the junction box with 2 screws provided Fig 2 3 Verify that the set screws in decorative canopy are fully retracted Not retracting them will cause unsightly scratches in the beautiful finish of the goose neck during installation Leave the protective plastic sleeves in place on the goose net Fig 3 4 Thread the wires from the fan through the barrel of the hanger bra...

Page 5: ...minal block with screw driver to avoid the wires loose Fig 4 and 5 5 Be sure to snap together the male and female plugs Fig 4 6 Push canopy down goose neck toward wall until the canopy lays flat against the wall surface covering the hanger bracket Tighten set screws in canopy Fig 6 SUPPLY CIRCUIT OUTLET BOX Neutral Brown Fan Hot Live Black OSC Hot Live Ground Blue Neutral Yellow Green Black Hot Br...

Page 6: ...r to wall speed control labeled To Light Note Perform this step if yours is a two dual circuit installation If this is a single circuit application this step will be ignored and the blade motor and oscillation motor will not be operated independently Hot Live household supply wire to wall speed control port labeled To Hot Live 4 Connect if present the wall speed control s ground wire directly to o...

Page 7: ...eed control knob is used to control the fan blade speed as follows 0 Turns the fan off 1 High Speed 2 Medium Speed 3 Low Speed B ON OFF Button This button is used to control the oscillating operation if yours is a two dual circuit installation Otherwise this knob will not function ...

Page 8: ... sure that your fan head s set screw is counter sunk into the bore hole in the flat part of the motor shaft Be careful that the blade brackets themselves are not bent in this process Do not operate your fan if it continues to vibrate Contact your Atlas Fan Co purveyor if the re installation of the blades does not resolve the problem 6 Fan Oscillation is irregular not smooth The decorative motor mo...

Page 9: ...porarily to hold the front motor cap and blade cage in place while you grease your oscillation mechanism Matthews Fan CO Atlas brand oscillation fans are mechanical and so depending upon the amount of use your new fan receives and the climate in which it is installed it may need its oscillation mechanism greased approximately every 6 months or as needed if oscillation noise occurs Step2 Use a lith...

Reviews: