Owner’s Manual
F6-AMIX
Multi-Function Analog Mixer Card
AtlasSound.com
– 11 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
Using the F6-AMIX
Follow these steps before turning on the F6-MF.
1. Turn all six level controls on the front panel of the F6-MF down.
2. Turn all six Channel Input level controls on the F6-AMIX down.
3. Turn the RCA & Mic/Line level controls down.
4. Decide if you are using a single music source into various channels of the F6-MF. If so, insert
connection from the source output into the RCA summed input jacks. Select the Channels of the
F6-MF you want the signal routed to via the RCA to Channel Bus Dip Switches.
5. Decide if you are using a single Mic or Line source into various channels of the F6-MF.
Example:
Paging Mic or a global announcement playback.
A. Wire the cable into the Mic/Line Input. If using an unbalanced Line source you must connect
the (G) and (-) pins together.
B. Assign the input to be either Line or Mic via the labeled dip switch.
C. If assigned to Mic, then decide if you need Phantom Power. If so, select the DP SW ON.
D. Select the Channels of the F6-MF you want the signal routed to via the Mic/Line to Channel
Bus
Dip
Switches.
6. Muting Input channels can be done by either VOX (Voice Operated Mute) or by an external Hard
Switch Contact Closure (RMT Mute Ext SW).
A. Select the Input signal you want to be muted via the Channel Mute REC (Receive) DP SW.
B. Using an external switch to activate the mute circuit is done by shorting the two RMT Mute
Ext SW pins together.
C. For voice activated mute, talk into the Mic and it will automatically activate the VOX
circuitry. If more sensitivity is needed to activate the mute, increase the VOX Sens until the
desired trigger point is achieved.
7. Remote Level can be applied to either or both the RCA input and the MIC/Line input.
Note:
Separate pots for each control port
will be required. Do not combine the ports.
A. Use a 10K Pot, only two leads/wires are needed. We suggest using Atlas AAVC-10K kit.
B. Insert the wires into the port, only part of the pot is needed. You may need to reverse the
wires on the pot leads for the correct level rotation.
8. Turn the F6-MF level controls to 50%.
Note:
The F6-MF levels are post or after all F6-AMIX input
signals. If these pots are turned down no signal will be sent to the amp channels.
9. Increase the level on Input Channels 1 - 6. Confirm the signal LED on the corresponding amp
channel is illuminated. Adjust the level as needed.
10. Adjust the RCA and Mic/Line levels as needed.