WIH 17-67 SERIES 

---------------------------------------------------------------------------------------------------------------------------------------------------------- 

INSTALLATION 

Provide the correct counter cut-out opening

 

and drop in. The vinyl gasket assures complete seating. A non-

toxic silicone seal may be used between the gasket and counter top (not required). The unit is supplied 

with a power cord and NEMA plug. Refer to the data plate on the control panel for the amperage and 

voltage information. Use a licensed electrician when installing power source. 

*

 

Control box on 14 1/4" side.

---------------------------------------------------------------------------------------------------------------------------------------------------------

OPERATION 

During operation the unit must be used with water and the thermostat must be set at position 

#10

.

 The thermostat dial has an off position and 

is numbered

 1 to 10 (Number 10 is the 

highest and mandatory setting

 for operation

)

-------------------------------------------------------------------------------------------------------------------------------- 

MAINTENANCE 

NEVER

 CLEAN PANS WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER 

CLEANING COULD SCAR, MARK AND/OR CORRODE PANS. 

DO NOT

 USE STEEL WOOL OR 

ABRASIVE PRODUCTS.TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO 

REMOVE ALL RESIDUES. 

FAILURE TO MEET THESE

 

CONDITIONS WILL VOID 

WARRANTY

-------------------------------------------------------------------------------------------------------------------------------- 

Summary of Contents for WIH 17-67 SERIES

Page 1: ...tion Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 1 WIH 37 Effective Date 2018...

Page 2: ...WITH CARRIER SERIAL NUMBER LOCATION INSTALLATION DATE _____________________________________________ MODEL _______________________________________________________ SERIAL _______________________________...

Page 3: ...d under the unit on operator s left Bottom of outer case can be removed for access to electrical components Specifications subject to change without notice SPECIFICATIONS STANDARD FEATURES g Fully ins...

Page 4: ...4 25KW 20 4 240V 4 25KW 17 7 L6 30P L6 30P 1000WATT 208V 5 0KW 24 0 240V 5 0KW 20 8 L6 30P L6 30P WIH 67 850WATT 208V 5 1KW 24 5 240V 5 1KW 21 3 6 50P L6 30P 1000WATT 208V 6 0KW 28 8 240V 6 0KW 25 0...

Page 5: ...when installing power source Control box on 14 1 4 side OPERATION During operation the unit must be used with water and the thermostat must be set at position 10 The thermostat dial has an off positi...

Page 6: ...crews 2 Remove 6 32 fiber nuts from the back of the control box 3 Mount the S S front plate to the Cut Out in apron 4 Attach the galvanized box to the S S front plate The unit is ready to be connected...

Page 7: ...99 238 S S Element Holder 18 1053 120V 850W Element 19 1054 208V 850W Element 20 1055 240V 850W Element 21 1056 120V 1000W Element 22 1057 240V 1000W Element 23 1058 208V 1000W Element 24 1002 Power C...

Page 8: ...urce use our Autofill or any backflow protection of your choice Please refer to your local code Any attempt to change or modify the Auto Fill system will void the warranty OPERATION To operate the Aut...

Page 9: ...on position Unit will not heat Call factory for service at 1 800 762 7565 Thermostat s not turned to the highest setting Food products not hot enough when placed in unit Food product not being stirred...

Page 10: ...TWO 2 HEATED WELLS SHOWN QUANTITY OF HEATED WELLS CAN BE FROM TWO 2 TO SIX 6...

Page 11: ...mpressor was not caused by the customer or end user Authorized replacement labor will be paid for a period of one year from date of installation Freight costs for defective unit to and from Atlas Meta...

Page 12: ...ice _______________________________________________ Atlas Metal will not approve excessive labor due to poor access to the unit being serviced If design does not allow reasonable access contact the fa...

Reviews: