11
PAGE
Repair Instructions Nr.183.09/00
PHE 50 S
Mounting
the field
1
Insert the field (2) into the motor hous-
ing (1) (mind the right position!) and se-
cure it with screws (3) and washers
(tightening moment = 8 Nm).
2
Fit the air deflector ring (4) on the motor
housing (1).
Mounting
the armature
1
Mount the seal ring (3) on the armature
shaft.
Press in the bearings (5) and (2).
2
Mount the rubber sleeve (1) and the bear-
ing ring (6) on the armature shaft (4).
3
4
1
2
6
4
5
2
1
3
6