Condensate drain valve, GX 7 and GX 11
Step
Action
1
Consult the installation instructions (see
Installation
).
2
Check that the electrical connections correspond to the local codes. The installation must
be earthed and protected against short circuits by fuses in all phases. An isolating switch
must be installed near the compressor.
3
Fit outlet valve (2), close it and connect the air net to the valve.
Connect condensate drain valve (Dm) and automatic drain outlet (Da) to a drain collector.
Close the valve.
Connect condensate drain valve (4) of the air receiver to a drain collector. Close the valve.
Oil system
Oil level sight-glass, GX 7 and GX 11
Step
Action
Check the oil level.
The oil level sight-glass (SG) should be between 1/4 and 3/4 full.
Instruction book
42
2920 7054 00