3.3
Electric cable size
Attention
Local regulations remain applicable if they are stricter than the values proposed below.
The voltage drop must not exceed 5% of the nominal voltage. It may be necessary to use
cables of a larger size than those stated to comply with this requirement.
GX 7
GX 11
Frequency
(Hz)
Voltage
(V)
Cable size
Cable size
IEC
(mm
2
)
(mm
2
)
50
200
16 (6 XLPE or EPR)
25 (16 XLPE or EPR)
50
230
10
16 (10 XLPE or EPR)
50
400
4
6
50
500
4
6
60
440/460
4
6
60
380
4
6
CSA/UL
AWG
AWG
60
200
6
6
60
208-230 / 460
8-8 / 10
6-6 / 8
60
575
12
10
3.4
Electrical connections
Always disconnect the power supply before working on the electrical circuit!
Instruction book
32
2920 7054 00