• Loading solenoid valve (Y1).
• The Elektronikon 001 regulator
Loading
As long as the working pressure is below the maximum limit, the solenoid valve is energised allowing control
air to flow to the unloader: the inlet valve opens completely and the unloading valve closes completely. The
compressor will run fully loaded (100% output).
Unloading
If the working pressure reaches the maximum limit, the solenoid valve is de-energised venting the control air:
the inlet valve closes completely and the unloading valve opens completely. The compressor will run fully
unloaded (0% output).
The GX 7 and GX 11 is equipped with the Elektronikon 001, an intelligent controller that will stop the
compressor after a variable period of unloaded operation:
• When the unloading pressure is reached after the first start and if there is no air consumption, the
compressor will run unloaded during 2 minutes and than stop.
• If there is a pressure request within the first 2 minutes after being stopped, the controller is expecting a
higher air consumption: the next time the unit will stop after 5 minutes of unloaded operation.
• If there is no pressure request earlier than 2 minutes after being stopped, the controller is expecting a lower
air consumption: the next time again it stops after 2 minutes of unloaded operation.
• If the compressor is stopped manually, it stops after 2 minutes unloaded operation.
The compressor will automatically restart when the net pressure drops to the minimum limit.
Instruction book
2920 7054 00
17
Summary of Contents for GX 11
Page 1: ...GX 7 GX 11 Instruction book ...
Page 2: ......
Page 6: ...10 1 PRESSURE EQUIPMENT DIRECTIVES 71 Instruction book 4 2920 7054 00 ...
Page 29: ...GX 7 and GX 11 Tank mounted 500 l optional Pack Instruction book 2920 7054 00 27 ...
Page 30: ...GX 7 and GX 11 Tank mounted 270 l Full Feature Instruction book 28 2920 7054 00 ...
Page 31: ...GX 7 and GX 11 Tank mounted 500 l optional Full Feature Instruction book 2920 7054 00 29 ...
Page 32: ...GX 7 and GX 11 Floor mounted Pack Instruction book 30 2920 7054 00 ...
Page 41: ...Electrical diagram GX 7 and GX 11 CSA UL Instruction book 2920 7054 00 39 ...
Page 74: ......
Page 75: ......