20/06/2011
PM 9845 0512 02
Page 26 of 36
9. Energy recovery data
9.1. Reference conditions
•
Air inlet temperature ........................... °C 20
•
Absolute air inlet pressure ................. bar 1
9.2. Effective operating pressure
•
7.5 bar units ........................................ bar 7
•
10 bar units ......................................... bar 9.5
•
13 bar units ......................................... bar 12.5
•
100 psi units ....................................... psi 100
•
125 psi units ....................................... psi 125
•
150 psi units ....................................... psi 150
•
175 psi units ....................................... psi 175
9.3. Maximum operating pressure
•
Oil side ................................................ bar 15
•
Water side........................................... bar 10
9.4. Reading settings
To read a setting, please refer to the section Elektronikon in the instruction manual of the compressor. In addition to other
data, the following temperatures can be read by pressing the scroll key:
•
The water inlet temperature of the ER unit.
•
The water outlet temperature of the ER unit.
9.5. Modifying settings
If the pre-programmed warning settings for the water temperatures are exceeded, a warning indication is shown on the
compressor control module:
Temperature input
Unit
Min. setting
Nom. setting
Max. setting
Energy recovery water inlet
°C
0
50
99
Delay at warning signal
sec
0
Please contact
Atlas Copco
255
Delay at start should be less than delay at
warning signal
sec
0
Please contact
Atlas Copco
255
Energy recovery water outlet
°C
0
Please contact
Atlas Copco
99
Delay at signal
sec
0
Please contact
Atlas Copco
255
Delay at start should be less than delay at
warning signal
sec
0
Please contact
Atlas Copco
255
To modify a setting, please refer to the section Modifying parameters in the instruction manual of the compressor.
Summary of Contents for ER S-1
Page 1: ...Atlas Copco Energy Recovery Stand Alone Kit Instruction book ...
Page 2: ......
Page 34: ...20 06 2011 PM 9845 0512 02 Page 32 of 36 Figure 17 9845 0070 00 Figure 18 9845 0071 00 ...
Page 35: ...20 06 2011 PM 9845 0512 02 Page 33 of 36 Figure 19 9845 0124 00 Figure 20 9845 0125 00 ...
Page 39: ......
Page 40: ...PM 9845 0512 02 2011 06 Printed in Belgium www atlascopco com ...