2. Loosen the square screw cap on the drive side
by locking the eccentric. Use a screwdriver to
lock the eccentric, place the screwdriver into
the groove at the end with the end cap.
3. Locate the bearings and seals to be replaced.
Pull out the eccentric together with the two
bearings the vibrator tube. Pull out from the end
with the end cap.
4. Press the two bearings out of the tube.
5. Assemble in the opposite order.
Storage
♦
Clean the machine properly before storage,
in order to avoid hazardous substances. See
section “Dust and fume hazard”.
♦
Always store the machine in a dry place.
♦
Keep the machine in a safe place, out of the
reach of children and locked up.
Disposal
A used machine must be treated and disposed
in such way that the greatest possible portion of
the material can be recycled and any negative
in
fl
uence on the environment is kept as low as
possible, and in accordance with local restrictions.
Always send used
fi
lters and drained oil remnants
to environmentally correct disposal.
The electronic and electrical devices may contain
potentially hazardous substances. Do not dispose
of them in the nature. Dispose them according to
local laws and regulations for the country of use.
According to the European directives 2002/95/EC
and 2002/96/EC.