background image

7

PROGRAMMING INSTRUCTIONS – CAFÉ PLUS

The 3 and 4 lane machines are programmed in a very similar manner to the Café mini. 
The  main  differences  have  been  highlighted                                               

  .

The five buttons are named BEV 1, BEV 2, BEV 3, BEV 4, STOP.                       

.

BEV  1  and  BEV  2  buttons  does  the  same  function  as  the  COFFEE  button  to 
increase/decrease  time  and  toggle  to  enable  or  disable  functions.  BEV  3  is  the 
equivalent  of  the  HOT  WATER  button  in  the  2  lane  Café  mini  and  is  primarily  for 
saving  and  moving  on  to  next  mode.                                                               

.

IN  the  Café  Plus,  to  get  hot  water  or  half  cup,  just  press  the  STOP  button  once  and 
then  the  BEV  button  of  your  choice  to  get  hot  water/half  cup  of  drink  from  that  lane.
A longer press of the STOP button and you can enter the MENU mode and follow the
same  instructions  as  the  Café  Mini  programming.                                               

.

NOTE  THAT  THE ATLANTIS  MACHINES  HAVE A  LOT  OF  OTHER  FEATURES 
LIKE  LANGUAGE  CHANGE  AND  CALIBRATION  WHICH  CAN  BE  ENABLED 
UNDER SUPERVISION OF AN AUTHORISED ENGINEER FROM THE COMPANY.

 Press  HALF  and  the  screen  would  show  CNTR  RESET.  Pressing  TEA  would  show 
YES. Then  you  have  to  enter  the  password  and  the  counters  of  coffee  and  tea  would 
be  reset  to  0.                                                                                                                     

Press  HALF  again  and  we  have  the  USER  MESSAGE  change  option.  Using  the 
COFFEE TEA and HALF buttons (for saving) you can actually change the name on the 
display  to  your  choice.  A  unique  feature  only  on  ATLANTIS  machines.
 Lastly pressing HALF would show CHANGE PASSWORD. Press TEA and the YES 
option appears. Press HALF again and ENTER the old password followed by the new 
password  twice.

                                                                                            .

 Press  HALF  again  and  the  machine  display  shows  “returns  to  the  regular  MAKE 
YOUR CHOICE mode.

USER’S MANUAL 

 Next mode on pressing HALF is the SET DEFAULT option. In you enable the same 
by imputing YES, then all settings of water, powder, temp etc would be restored to the 
factory  settings.                                                                                                     

      .

 Press  Half  again  and  we  now  enter  the  SET  FLUSH  mode.  Here  we  have  the  following 
options  (all  available  using  the  COFFEE/TEA  switches).  If  we  want  to  flush  the  machine 
at  regular  intervals,  specially  when  not  in  use,  then  we  should  enable  – YES,  this  option. 
We recommend this as well, because it not only cleans the water pathways, but also keeps 
them warm. If you choose YES, then you can set the flush time interval to 10/ 30/60/90 mins 
depending  upon  usage  of  the  machine.  If  the  machine  is  used  extensively,  then  a  higher 
interval is recommended.                                             

 .

 

8

Specific  fault  message  will  be  displayed  when  the  m/c  stops  dispensing.
List of fault messages, their possible cause and remedial action are listed blow.

TROUBLESHOOT

1. Check heater fuse. If fuse has blown off, replace it.
2. Check loose connections continuity at heater/
    fuse/holder/relay/terminals 
3. Check  loose connections at main PCB connector 
    and rectify.
4. Check 230 volt AC supply across heater terminal,
    if power supply not detected replace heater.
5. If power supply not detected, check DC signal 
    across relay terminals.
    a.) If power supply not detected replace relay.
    b.) If power supply not detected, then replace PCB. 

1. If display show “Heating....”
    for more than 10 minutes 

2. If display shows 
    “Water tank empty”

3. Overheating in boiler tank

HOT BEVERAGE DISPENSER

1. Check water level in bottle top
2. Check continuity of sensor wire from PCB to tank

1. check loose connection of temperature sensor on
the boiler.
2. Check DC signal across heater relay terminal
a) If power supply not detected, replace repay.
b) if power supply not detected, replace 
temperature sensor. 

4. Electric shock

5. As soon as machine is 
switched on power supply
trips.

1. Check earthing / polarity in supply socket.
2. Check water leaking inside the machine and 
rectify it.
3. Ch loose connection of earthing wire with 
machine body.
4. check continuity between machine body & earth
pin on 15 Amp power plug. if continuity is not there 
replace power cord

1. Check correct rating of MCB.

2. Remove 15 Amp fuse & switch on. If it is tripping

again, reconnect the same & if it not tripping, 

replace heater. 