4 Tefl on plates are provided to facilitate the introduction of the 2 generators
in relation to each other:
• Put one plate under each of the 4 feet of the generator to be moved,
• Position the generator,
• Remove the Tefl on plates.
fi gure 5 - cable trays
Tefl on plates (x4)
4.8.
Installing the LPB bus cable trays
Position the 2 trays for the LPB bus cable on the rear of the 2 generators and
secure them using the 4 self-tapping screws provided.
fi gure 4 - Tefl on plate positioning
}
4 self-tapping screws provided
The roof of each generator must be drilled (Ø 4 bit); to do so, use the trays
as scale.