Recommendations on use
Recommendations on use
There is no point in setting the heating to maximum, the room temperature will not rise any quicker.
When you air the room, switch off the heating by setting cursor
A
to
.
If you will be away for several hours, consider reducing the temperature.
Locking the controls
Wheel
B
can be locked in position or its range restricted to prevent inappropriate use (
by children, etc..
).
a) Unhook the device from the wall bracket.
b) Detach pins
P
from their supports on the rear of the control box.
c) Select position
N
to lock the wheel or position
L
to restrict its adjustment range.
Select one of the positions
M
to lock the switch in the desired mode.
Problems
Check
The device does not
heat
- Check that the programming unit is in Comfort mode .
- Check that the premise circuit breakers are triggered or that the load shedder (
if you
have one
) has not interrupted the device’s power supply.
- Check the air temperature in the room.
The device heats all
the time
- Make sure that it is not in a draft and that the temperature setting has not been chan-
ged. This unit with electronic control is equipped with a microprocessor that can be dis-
tribued by some severe mains voltage disturbances (
outside EC standards defi ning the
disturbance protection level
). If there are any problems (
thermostat blocked, etc.
) switch off
the unit power supply (
fuse, circuit breaker, etc.
) for about 5 minutes to allow the unit to
start again.
The device’s surface
is very hot
It is normal for the device to be hot when it is operating. The maximum surface tempera-
ture is restricted in accordance with the NF Electricité Performance standard. However, if
you think that your device is always too hot, check that the output is suitable for the area
of your room (
we recommend 100W / m
2
) and that the device is not placed in a draught,
which would disrupt its setting.
The device does not
follow the program-
ming instructions
- Ensure that you use the programming unit correctly (
refer to the instructions manual
), that
the programmer is correctly lodged in its housing and that it is operating normally (
check
the condition of the batteries
).
This device is electronically controlled and its microprocessor can be affected by significant local interferences (
out-
side the EU norms defining the level of protecton against interferenc
e).
If a problem should arise (
locked thermostat, etc
), cut the power supply to the device (
fuse, circuit breaker, etc
) for
approx. 10 minutes to reset the device.
If the problem recurs frequently, have your electricity supply checked by your electricity supplier.
In case of problem
For an absence of :
Less than 2 hours
Do not alter the controls.
2 to 24 hours
Set cursor
A
to .
More than 24 hours or in summer
Set cursor
A
to
.
16
14
15
To activate Programming mode, set cursor
A
to .
The device will then respond to a programming device for selection of the Comfort and Eco temperature periods
by connecting the control wire to a programming unit or another device fitted with a time clock to save on energy.