Installation instructions "1552 - EN"
Burner description
1 Brief description
ATL F10E2-1 range burners are compact fuel burners which meet standards on burners with air flow adjustment:
• They are delivered with cables connected.
• They are fitted to the boiler using a welded flange
• All of the parts are assembled on an easily accessible plate.
• The plate containing the parts is located for optimal maintenance.
• Flame surveillance is carried out by an infra red cell.
• Ignition is by electronic transformer.
• The nozzle line is reheated.
Envisaged use
ATL F10E2-1 range burners are designed to specifically operate with "hot water furnaces" for heating premises and domestic hot
water.
• Fuel: standard fuel oil and low-sulphur fuel oil (max. viscosity: 6 mm²/s at 20°C).
2 Dimensions
Dimensions (in mm)
Possible drill holes in the fire box door
Leave a minimum space of 0.80 m behind the burner, free of any obstacles to allow for maintenance.
01083