10
f
ilter
r
ePlaCement
IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY
EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.
Always disconnect power to the fixture before performing any service or maintenance
.
1. Disconnect power to the
SANITAIRE
®
.
2.
Turn the two white plastic latches on each of the top corners of the lower filter grill and allow the grill to pivot out to expose
the filter behind the grill
(See Figure 10)
. Once the filter is exposed, slide it from its location
(Figure 11)
.
3.
Once the filter is removed, use a vacuum to remove any trapped dust or dirt in and
along the filter frame. Be careful not to damage the protective mesh located in the
back of the filter frame. Contact factory if this mesh is ever damaged or appears to
need replacement.
4.
Position the replacement filter so that the arrows on the filter showing the flow
direction face inwards to the unit and slide the filter into the frame
(See Figure 12)
.
5.
Once the filter is in place, pivot the filter grill back into place and rotate the two white
plastic latches securing the filter in place.
u
nit
P
laCement
SANITAIRE
®
Model RSM2680 fixture is recommended for use in large conference rooms, auditoriums or any large area which
may or may not contain occupants. For maximum efficiency, the
SANITAIRE
®
should be located as centrally as possible.
Access to the room does not need to be controlled while the fixture is operating. The louvered exhaust panel, on the top of the
SANITAIRE
®
Germicidal Ultraviolet Room Air Sanitizer, limits ultraviolet radiation from passing into the room, protecting the
room’s occupants from ultraviolet exposure.
To ensure safe and proper use, make sure the location follow these recommendations:
• SANITAIRE
®
should be operated indoors only.
•
Selected location should allow enough space to allow free air to enter the lower filter grills and be clear of any obstruction
that would hinder or reduce smooth air flow in the grills.
• Area selected should be clean and free from dust and particles which may be drawing into the intake grills.
• Has a properly grounded electrical outlet within approximately 15 feet of the unit.
• The
SANITAIRE
®
should not be operated in areas with ceiling heights lower than 8 feet.
• SANITAIRE
®
is not recommended to be operated in areas that have high gloss finished ceilings, which may cause excessive
reflection back into the room from the top exhaust louvers. (Contact the factory for further information.)
Figure 10
Figure 11
Figure 12