8
K
ey
s
witCh
and
P
ower
C
ontrol
The power switch is located at the front of the unit on the lower right side. It allows the operator to run the unit in two modes:
BLOWER ONLY
(Left) or
LAMP & BLOWER
(Right). The center position is the
OFF
.
Figure 4 –
SANITAIRE
®
RSM2680
Power Control
Blower Only
OFF
Lamps & Blower
l
amP
and
f
ilter
r
eset
B
uttons
The reset buttons are located at the front of the unit on the lower left side. The lamp
and filter timer should be reset after each time the lamps and or filters are replaced.
This is accomplished by holding down the reset button for about five seconds until
the timer lights flash and the green light comes on.
Figure 5 –
SANITAIRE
®
RSM2680
Lamp and Filter Reset Buttons
INSTALLATION
l
amP
i
nstallation
IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY
EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.
Always disconnect power to the fixture before performing any service or maintenance
.
Ultraviolet lamps are easily damaged and may cause injury if broken. Exercise care when handling.
1. Disconnect power to the
SANITAIRE
®
.
2. Using the key provided unlock the front and rear doors and rotate all latches on each of these doors so that they face vertical
and open the front and rear doors.
(“Lamp Installation” continued on Page 9)