Atlantic Ultraviolet Nutripure 2B-SC Owner'S Manual Download Page 8

8

t

eChniCal

 a

ssistanCe

Atlantic Ultraviolet Corporation

®

 maintains a qualified team of application specialists that can provide technical assistance, which 

may be required during the use of this equipment. For any questions, concerns, or technical assistance, regarding this model or 
any of our other products, contact our application specialists. Contact options can be found in the “

User Assistance

” section on 

the back page of this manual.

MAINTENANCE 

 

Always disconnect power to the 

Nutripure

®

  before performing any service or maintenance.

• 

The

 Nutripure

®

 is designed to operate with a minimal amount of maintenance. 

• 

A regular cleaning cycle of the 

STER-L-RAY

®

 Germicidal Ultraviolet Lamp(s), interior, 

Promate

TM

 

sight glass and intake 

filter(s) 

MUST

 be established, and carefully maintained, based on inspection and experience. The frequency of cleaning will 

vary with the conditions surrounding each installation. It is recommended that the ultraviolet lamp(s) interior, sight glass, and 
filters be cleaned at least once every three (3) months.

• 

The 

STER-L-RAY

®

 

Germicidal Ultraviolet lamp(s) used in the 

Nutripure

®

 have a manufacturer’s rated average effective 

life of 10,000 hours. 

STER-L-RAY

®

 

Lamp(s) may operate longer than their rated effective life, but the reduction 

in ultraviolet output will make it impractical to use past the manufacturer’s rated life. For maximum efficiency lamp 
replacement is recommended every 10,000 hours of operation or about one (1) year of continuous use.

• 

Unless lamp replacement is due to failure or breakage, it is recommended that all lamps be replaced at the same time.

l

amP

 i

nstallation

, r

ePlaCement

or

 C

leaning

IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY 

EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.

 

Always disconnect power to the fixture before performing any service or maintenance.

 

Ultraviolet lamps are easily damaged. Exercise care when handling lamps.

1.  Disconnect power to the sanitary conditioner and unplug from the electrical outlet.

2.  Remove access cover. (Removal of the 

Nutripure

®

 access cover will cause the interlock switch to interrupt power to the 

lamps and blower. 

DO NOT

 attempt to bypass or circumvent the interlock switch or its safety feature.)

3.  Remove 

STER-L-RAY

®

 

lamp(s), carefully press lamp against the spring-loaded lampholder, when 

STER-L-RAY

®

 

lamp 

pin clears the stationary lampholder, pull 

STER-L-RAY

®

 

lamp out, and away from 

Nutripure

®

.

4.  Moisten a clean, lint-free cloth with denatured alcohol and clean lamp(s).

5.  When 

STER-L-RAY

®

 

lamp(s) have been removed, cleaned and safely set aside, remove any loose dust or dirt from the 

interior of the 

Nutripure

®

 with a soft dry cloth, or vacuum.

6.  To remove any dust, dirt, fingerprints, smears, etc, from the outer surfaces of the conditioner, moisten a clean, lint-free cloth 

with denatured alcohol and wipe down the  conditioner. Buff out any streaks, left from the cleaning, using a soft dry cloth.

7.  Install 

STER-L-RAY

®

 

lamp(s), insert lamp pin into spring-loaded lampholder. Carefully press 

STER-L-RAY

®

 

lamp against 

the spring-loaded lampholder. Align lamp pin with stationary lampholder. Slowly ease the pressure until 

STER-L-RAY

®

 

lamp is fully seated in lampholders.

8.  Verify that 

STER-L-RAY

®

 

lamp(s) is properly seated.

9.  Repeat until all 

STER-L-RAY

®

 

lamps have been cleaned and properly reinstalled.

10.  Install Access Cover. Restore power to the 

Nutripure

®

.

Avoid exposure to direct or reflected germicidal ultraviolet rays. Germicidal 

ultraviolet rays are harmful to the eyes and skin.

11.  Wear personal protection equipment, then verify operation by viewing 

STER-L-RAY

®

 

lamps(s). If the fixture is not 

operating properly, go to 

“Troubleshooting”

 section.

Summary of Contents for Nutripure 2B-SC

Page 1: ...96F4 September 2019 2019 Atlantic Ultraviolet Corporation Read and Follow All Safety Instructions Save These Instructions Installation Operation Maintenance Models 2B SC 3B SC 4B SC 4B ASC 5B SC 5B ASC 6B SC 6B ASC Models 2B SC 3B SC Models 4B ASC 5B ASC Models 6B ASC Owner s Manual Owner s Manual ...

Page 2: ...lected by the Atlantic Ultraviolet Corporation and are believed to be correct However no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein Specifications and information are subject to change without notice SAFETY WARNINGS 3 SAFETY INSTRUCTIONS 3 SAFETY LABELING 4 CAUTION 4 PRODUCT APPLICATION 5 Construction 5 Principle of Operation 5 L...

Page 3: ...er if lamp cable lamp connection power cord and or plug are damaged or if any other damage to the sanitary conditioner is visible or suspected 8 Electrical power supplied to the sanitary conditioner MUST match power requirements listed on the sanitary conditioner 9 Plug the sanitary conditioner into an approved ground fault circuit interrupt GFCI receptacle 10 Do not operate without proper electri...

Page 4: ...on User s Responsibility Label PN 00 0356 Measures 5 x 1 15 16 1 Required Hg Lamp Contains Mercury Label PN 00 0297 Measures 75 x 2 50 2 Required UV ULTRAVIOLET RADIATION Protect eyes and skin from direct and reflected radiation Turn off and disconnect power before servicing HAZARDOUS VOLTAGE DANGER 00 0291A 00 0291A Label Danger HV UV Print Specs 5 x 4 9375 PMS109 PMS185 outdoor Black White Mylar...

Page 5: ...ilter Models 4B ASC 5B ASC and 6B ASC only Figure 1 Installation of Pipe Collar and Pedestal Legs Principle of Operation The Nutripure Sanitary Conditioner design has been carefully conceived to provide germicidal ultraviolet exposure for air disinfection The treated air is used in the headspace of liquid storage tanks helping to prevent condensation The dosage as it applies to ultraviolet disinfe...

Page 6: ... RAY UV Lampwith ArmorliteTM 1 Set Pedestal legs 1 2 TV Tank Vent optional 1 Pipe Collar Screen 1 Pipe Collar 1 Pipe Collar Gasket Hardware Model 4B SC 1 72 CFM free air displacement 1 lamp Nutripure 1 STER L RAY UV Lampwith ArmorliteTM 1 Set Pedestal legs 1 4 TV Tank Vent optional 1 Pipe Collar Screen 1 Pipe Collar 1 Pipe Collar Gasket Hardware Model 5B SC 1 140 CFM free air displacement 2 lamp N...

Page 7: ...legs onto the outside of the enclosure Sanitary Conditioner Place pipe collar gasket onto the vent pipe Place sanitary conditioner collar over vent pipe onto gasket Level the sanitary conditioner by adjusting pedestal legs Once level tighten locking nut against enclosure Fasten collar to vent pipe using the supplied 20 hex head bolts Select suitable vent pipe Attach tank vent Lamp Installation Fol...

Page 8: ...OR A FACE SHIELD AS WELLAS GLOVES Always disconnect power to the fixture before performing any service or maintenance Ultraviolet lamps are easily damaged Exercise care when handling lamps 1 Disconnect power to the sanitary conditioner and unplug from the electrical outlet 2 Remove access cover Removal of the Nutripure access cover will cause the interlock switch to interrupt power to the lamps an...

Page 9: ...e side Skip to step 7 DO NOT use a high velocity water stream to clean the filter A high velocity stream may damage the filter s internal fibers 5 To wash PromateTM filter s flush thoroughly with clean water either by immersing or with a fine spray in the direction opposite to the airflow If the filter s is contaminated with heavy grease concentrations wash filter s with a detergent solution NOTE ...

Page 10: ... stainless steel Shields the filter from direct exposure to the sun dust falling debris and liquid sprays See Figure 3 below This accessory must be ordered at the time of initial equipment purchase All other accessories can be ordered and installed at the time of initial equipment purchase and installation or added at a later date For more information and purchasing contact our offices weekdays be...

Page 11: ...eplace ballast STER L RAY Germicidal Lamp not properly seated Confirm contact between lamp and lampholder is tight and lampholder is making full contact with lamp If the above measures fail to correct the problem s contact our UV Application Specialists Contact options can be found in the User Assistance section of this manual located on the back page REPLACEMENT PARTS Table 2 Replacement Parts MO...

Page 12: ...p with ArmorLiteTM 05 6011 05 6011 05 6011 05 6011 05 6011 05 6011 05 6013 05 6013 Quantity of Lamps 1 2 1 1 2 2 4 4 Power Consumption W 25 50 25 25 50 50 128 128 Ultraviolet Output Watts 8 5 17 8 5 8 5 17 17 45 6 45 6 Tank Vent 2 TV 40 1024B 2 TV 40 1024B 4 TV 40 1200B 4 ATV 40 1028B 4 TV 40 1200B 4 ATV 40 1028B 6 TV 40 0003A 6 ATV 40 0058A Length inches 6 1 32 6 1 32 6 16 1 4 6 16 1 4 14 1 2 22 ...

Page 13: ...13 MAINTENANCE NOTES ...

Page 14: ...14 MAINTENANCE NOTES ...

Page 15: ...15 MAINTENANCE NOTES ...

Page 16: ...eipt and shall notify us at our main office in writing of claims including claims of breach of warranty within thirty 30 days after the Buyer discovers or should have discovered the facts upon which the claim is based Failure of the Buyer to give written notice of a claim within the time period shall be deemed to be a waiver of such claim The provisions of the above warranty are our sole obligatio...