SAFETY LABELS 

CAUTION 

It is the User’s responsibility to determine and validate the suitability of this equipment for use in the user’s system or process. 

No warranty or representation is made by the manufacturer with respect to the suitability or performance of this equipment or to the 
results that may be expected from its use.

Indoor Use Only 

– The equipment must be sheltered from exposure to the elements and extremes in temperature.  

Temperature range: 40 °F to 100 °F.

The user should periodically inspect, clean as necessary and confirm the presence and good legibility of the Product safety labels. 
Contact the factory for replacement labels in the event that any of the labeling is missing or illegible.

This Nutripure Sanitary Conditioner has the following Warning and Advisory Labels 
Attached Prior to Shipment: 

Danger Label: Hazardous Voltage / Ultraviolet Radiation  
PN# 00-0196A1 (Measures: 2.5” x 2.25”) (2-Required)

Warning Germicidal UV Label PN# 00-0198A1 
(Measures: 1.25” x 3”) (2-Required) 

Caution: User’s Responsibility Label PN# 00-0356  
(Measures: 5” x 1-15/16”) (1-Required) 

Hg-Lamp Contains Mercury Label PN# 00-0297  
(Measures: .75” x 2.50”) (2-Required) 

UV

ULTRAVIOLET 

RADIATION

Protect eyes and skin from 

direct and reflected radiation.

Turn off and disconnect

power before servicing.

HAZARDOUS

VOLTAGE

DANGER

!

00-0291A

00-0291A

Label: Danger HV/UV 

Print Specs: 5" x 4.9375" 

PMS109, PMS185/outdoor & Black 

White Mylar w/Varnish 

Rounded corner

UV

ULTRAVIOLET 

RADIATION

Protect eyes and skin from 

direct and reflected radiation.

DANGER

!

This luminaire is designed for use with germicidal

ultraviolet lamps and must be installed in 

compliance with competent technical directions 

so that the user's eyes and bare skin will not be 

subjected to injurious rays.

WARNING

!

No. 00-0198A1

  

CAUTION

!

It is the User's responsibility to determine and validate the suitability of this 
equipment for use in his system or process. No warranty or representation 
is made by the manufacturer with respect to the suitability or performance 
of this equipment or to the results that may be expected from its use. 

00-0356

Label: Caution: User’s Res

Print Specs: 5" x 1-15/16"

PMS185/outdoor & Black 

White Mylar w/Varnish 

Rounded corner

00-0356

Summary of Contents for Nutripure 2B-SC

Page 1: ...96F4 September 2019 2019 Atlantic Ultraviolet Corporation Read and Follow All Safety Instructions Save These Instructions Installation Operation Maintenance Models 2B SC 3B SC 4B SC 4B ASC 5B SC 5B ASC 6B SC 6B ASC Models 2B SC 3B SC Models 4B ASC 5B ASC Models 6B ASC Owner s Manual Owner s Manual ...

Page 2: ...lected by the Atlantic Ultraviolet Corporation and are believed to be correct However no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein Specifications and information are subject to change without notice SAFETY WARNINGS 3 SAFETY INSTRUCTIONS 3 SAFETY LABELING 4 CAUTION 4 PRODUCT APPLICATION 5 Construction 5 Principle of Operation 5 L...

Page 3: ...er if lamp cable lamp connection power cord and or plug are damaged or if any other damage to the sanitary conditioner is visible or suspected 8 Electrical power supplied to the sanitary conditioner MUST match power requirements listed on the sanitary conditioner 9 Plug the sanitary conditioner into an approved ground fault circuit interrupt GFCI receptacle 10 Do not operate without proper electri...

Page 4: ...on User s Responsibility Label PN 00 0356 Measures 5 x 1 15 16 1 Required Hg Lamp Contains Mercury Label PN 00 0297 Measures 75 x 2 50 2 Required UV ULTRAVIOLET RADIATION Protect eyes and skin from direct and reflected radiation Turn off and disconnect power before servicing HAZARDOUS VOLTAGE DANGER 00 0291A 00 0291A Label Danger HV UV Print Specs 5 x 4 9375 PMS109 PMS185 outdoor Black White Mylar...

Page 5: ...ilter Models 4B ASC 5B ASC and 6B ASC only Figure 1 Installation of Pipe Collar and Pedestal Legs Principle of Operation The Nutripure Sanitary Conditioner design has been carefully conceived to provide germicidal ultraviolet exposure for air disinfection The treated air is used in the headspace of liquid storage tanks helping to prevent condensation The dosage as it applies to ultraviolet disinfe...

Page 6: ... RAY UV Lampwith ArmorliteTM 1 Set Pedestal legs 1 2 TV Tank Vent optional 1 Pipe Collar Screen 1 Pipe Collar 1 Pipe Collar Gasket Hardware Model 4B SC 1 72 CFM free air displacement 1 lamp Nutripure 1 STER L RAY UV Lampwith ArmorliteTM 1 Set Pedestal legs 1 4 TV Tank Vent optional 1 Pipe Collar Screen 1 Pipe Collar 1 Pipe Collar Gasket Hardware Model 5B SC 1 140 CFM free air displacement 2 lamp N...

Page 7: ...legs onto the outside of the enclosure Sanitary Conditioner Place pipe collar gasket onto the vent pipe Place sanitary conditioner collar over vent pipe onto gasket Level the sanitary conditioner by adjusting pedestal legs Once level tighten locking nut against enclosure Fasten collar to vent pipe using the supplied 20 hex head bolts Select suitable vent pipe Attach tank vent Lamp Installation Fol...

Page 8: ...OR A FACE SHIELD AS WELLAS GLOVES Always disconnect power to the fixture before performing any service or maintenance Ultraviolet lamps are easily damaged Exercise care when handling lamps 1 Disconnect power to the sanitary conditioner and unplug from the electrical outlet 2 Remove access cover Removal of the Nutripure access cover will cause the interlock switch to interrupt power to the lamps an...

Page 9: ...e side Skip to step 7 DO NOT use a high velocity water stream to clean the filter A high velocity stream may damage the filter s internal fibers 5 To wash PromateTM filter s flush thoroughly with clean water either by immersing or with a fine spray in the direction opposite to the airflow If the filter s is contaminated with heavy grease concentrations wash filter s with a detergent solution NOTE ...

Page 10: ... stainless steel Shields the filter from direct exposure to the sun dust falling debris and liquid sprays See Figure 3 below This accessory must be ordered at the time of initial equipment purchase All other accessories can be ordered and installed at the time of initial equipment purchase and installation or added at a later date For more information and purchasing contact our offices weekdays be...

Page 11: ...eplace ballast STER L RAY Germicidal Lamp not properly seated Confirm contact between lamp and lampholder is tight and lampholder is making full contact with lamp If the above measures fail to correct the problem s contact our UV Application Specialists Contact options can be found in the User Assistance section of this manual located on the back page REPLACEMENT PARTS Table 2 Replacement Parts MO...

Page 12: ...p with ArmorLiteTM 05 6011 05 6011 05 6011 05 6011 05 6011 05 6011 05 6013 05 6013 Quantity of Lamps 1 2 1 1 2 2 4 4 Power Consumption W 25 50 25 25 50 50 128 128 Ultraviolet Output Watts 8 5 17 8 5 8 5 17 17 45 6 45 6 Tank Vent 2 TV 40 1024B 2 TV 40 1024B 4 TV 40 1200B 4 ATV 40 1028B 4 TV 40 1200B 4 ATV 40 1028B 6 TV 40 0003A 6 ATV 40 0058A Length inches 6 1 32 6 1 32 6 16 1 4 6 16 1 4 14 1 2 22 ...

Page 13: ...13 MAINTENANCE NOTES ...

Page 14: ...14 MAINTENANCE NOTES ...

Page 15: ...15 MAINTENANCE NOTES ...

Page 16: ...eipt and shall notify us at our main office in writing of claims including claims of breach of warranty within thirty 30 days after the Buyer discovers or should have discovered the facts upon which the claim is based Failure of the Buyer to give written notice of a claim within the time period shall be deemed to be a waiver of such claim The provisions of the above warranty are our sole obligatio...

Reviews: