b.
Bridge mode configuration (868)
The following information applies to ACW / 868-DINRS and ACW / 868-DINRS +.
In this operating mode, the data of the serial link is transmitted directly in local radio to another ATIM device
(ACW / ARM) and vice versa. Typically, with another ACW / 868-DINRS or DINRS +.
Note:
Frames must not exceed 512 bytes.
Note:
It is advisable to change the default 'Channel' radio channel.
✓
1: Serial parameters: The ACW / 868-DINRS module has a serial link that you can set in RS232 or
RS485 mode. You must also specify the speed (Baudrate) you want to use: 4800, 9600, 19200, 38400,
57600 and 115200 are available. The other default parameters (and not configurable for RS485 type
connections) are: 1 stop bit, no parity, no flow control and 8 data bits.
✓
2: Bridge mode: The 'Short range radio' option must be checked to activate the bridge mode in local
radio. The 'Advanced' option is reserved for advanced use of the radio module.