ATIM Cloud Wireless
®
Bridge Mode RS232/485
DINRS
User Guide
Concerned models:
ACW/SF8-DINRS
[Software 2.3 Revision B.0 or previous]
ACW/LW8-DINRS
[Software 1.7 Revision A.3 or previous]
ACW/868-DINRS
ACW/868-DINRS+
Page 1: ...Cloud Wireless Bridge Mode RS232 485 DINRS User Guide Concerned models ACW SF8 DINRS Software 2 3 Revision B 0 or previous ACW LW8 DINRS Software 1 7 Revision A 3 or previous ACW 868 DINRS ACW 868 DI...
Page 2: ...figuration LoRaWAN 15 d Slave Modbus configuration SF8 868 16 e Modbus Slave mode configuration LoRaWAN 21 f Modbus Master Mode configuration SF8 23 g Modbus Master Mode configuration LoRaWAN 25 Confi...
Page 3: ...does not represent a commitment on the part of ATIM radiocommunications ATIM radiocommunications provides this document as is with no warranty of any kind express or implied including but not limited...
Page 4: ...and EN300 220 1 v2 4 1 Environmental recommendations Explosive atmosphere Except for the ACW ATEX line specifically intended for this purpose do not use ACW radio modems in the presence of flammable...
Page 5: ...pean Union This symbol appears on a product or its packaging to indicate that the product may not be discarded with another household waste Rather it is your responsibility to dispose of this product...
Page 6: ...C operating 40 C to 70 C storage Mounts to DIN Rail Power Supply 10 30Vcc Frequency 865 870 MHz Power RS model 25 mW 14 dBm Power RS model 500 mW 27 dBm Rate Local 1 2 to 115 Kbit s Sigfox 100 bps LoR...
Page 7: ...ade of insulating material PVC ABS fiberglass it is possible to simply use a small whip wave antenna Ref ATIM ANT868 12FSC This antenna must be firmly screwed on the SMA connector is positioned vertic...
Page 8: ...osition USB side For an RS485 connection you have the option to activate the 120 termination resistor up SMA side resistor activated down USB side resistor deactivated The USB connector is used to con...
Page 9: ...to emit a test frame in order to validate the installation on site The sending of test frames is only available in the operating modes described in the following subsections Modbus Master Mode In Mod...
Page 10: ...he current configuration of the connected module is retrieved and displayed The different configuration modes are described below Once the configuration is done you just have to click on the Write key...
Page 11: ...following information applies to the ACW SF8 DINRS In this mode of operation the data of the serial link is directly transmitted as such on the Sigfox network Note If the frames sent via the serial li...
Page 12: ...Baudrate you want to use 4800 9600 19200 38400 57600 and 115200 are available The other default parameters and not configurable for RS485 type links are 1 stop bit no parity no flow control and 8 dat...
Page 13: ...isable to change the default Channel radio channel 1 Serial parameters The ACW 868 DINRS module has a serial link that you can set in RS232 or RS485 mode You must also specify the speed Baudrate you w...
Page 14: ...mode only two radio rates are available 9600 and 19200bps as well as 16 channels To increase the radio range decrease the Baudrate rate The Channel channel will have to be chosen according to the env...
Page 15: ...work Note Frames must not exceed 512 bytes 1 Serial parameters The ACW DINRS module has a serial link that you can set in RS232 or RS485 mode You must also specify the speed Baudrate you want to use 4...
Page 16: ...ation the ACW DINRS is seen as a Modbus slave on the RS232 or RS485 serial link as well as by the radio Note Les trames Modbus ne doivent pas d passer 512 octets 1 Serial parameters The ACW DINRS modu...
Page 17: ...ttings Baudrate and Channel Compatibility with older generation radio modems ARM is ensured by checking the box Compatibility with ARM modem In this operating mode only two radio rates are available 9...
Page 18: ...ule address from 0 to 255 This is an advanced setting Do not edit 60008 255 Modem Address of the remote radio module from 0 to 255 broadcast This is an advanced setting Do not edit 60009 1200 Or the v...
Page 19: ...Bm 5 dBm 7 dBm 10 dBm 12 dBm 14 dBm 20 dBm only with ACW 868 DINRS 23 dBm only with ACW 868 DINRS 27 dBm only with ACW 868 DINRS 255 for an auto configuration Note Not all values are possible dependin...
Page 20: ...ta to SIGFOX and a timeout of 500ms if you modify all the configuration registers 60007 to 60011 Finally if you send the 50 data registers in local radio a time out of 1 2s must be respected If you se...
Page 21: ...You can write up to 16 registers in a single Modbus request 1 Serial parameters The ACW LW8 DINRS module has a serial link that can be set in RS232 or RS485 mode You must also specify the speed Baudra...
Page 22: ...ntifier with which the ACW LW8 DINRS will respond Slave Modbus mode Modbus table Data written in any register is sent directly to the LoRaWAN network Only the number of written records will be sent Su...
Page 23: ...has a serial link that you can set in RS232 or RS485 mode You must also specify the speed Baudrate you want to use 4800 9600 19200 38400 57600 and 115200 are available The other default and non config...
Page 24: ...ad Input Registers Operating mode Every Statement period a Modbus frame is sent on the RS232 485 serial link Then if there are no errors the read registers are sent to Sigfox as described in the next...
Page 25: ...ust also specify the speed Baudrate you want to use 4800 9600 19200 38400 57600 and 115200 are available The other default and non configurable parameters are 1 stop bit no parity no flow control and...
Page 26: ...r each frame sent and if there are no errors the read registers are sent to the LoRaWAN network as described in the next section LoRaWAN frame format Data is sent over the LoRaWAN network in the follo...
Page 27: ...68 DINRS There are three ACW DINRS which will be noted here by ACW A ACW B and ACW M Master It is desired that ACW M communicate with ACW A and ACW B but that ACW A and ACW B communicate only with ACW...
Page 28: ...e in the following example Material description There are three ACW RS which will be noted here by ACW A ACW B and ACW S The ACW S Slave is an ACW RS SF8 which means it will be the only one able to co...
Page 29: ...cal to ACW S the default configuration is required for the ACW A The ACW B meanwhile is configured in bridge mode but requires a radio configuration different from the ACW S and thus also the ACW B Ag...
Page 30: ...han the ACW S and the ACW A PLC 1 or PLC 2 or the two PLCs will write the radio configuration of the ACW S allowing communication with the ACW B 1 ACW S Slave Modem 7 Baudrate 19200 Channel 64 Baudrat...
Page 31: ...ing modems on the ACW platform Log in to the web platform http acw atim com to access your devices and view your data Your login details will be provided by email to the shipping of your order In the...
Page 32: ...FOX network To register the modem with the SIGFOX network open an Internet browser and go to https backend sigfox com Your product is now being imported into your SIGFOX account The import may take se...
Page 33: ...twork is issued when the product is powered on The device must first be provisioned on the required network at one of the operators Orange or Objenious for example or existing private gateways A new p...
Page 34: ...ol File menu Update Replace the USB cable If you receive an Error writing configuration unplug the USB cable and plug it back in b Radio data not received Check whether the power supply is correctly c...