10
ATIM_ACW-TMxP_UG_EN_V1.0
d.
Opening the ACW housing
The housing must be opened to access both the terminal block and the mini-
USB port used to configure the module.
To do this, insert a screwdriver into the slot and tilt it downward to lift the inside
tab (see photo). Then pull on the back panel to separate the two parts of the
housing.
e.
Installation
Install the modem at least 2 m above the ground and not right against the wall
—
ideally at least 20 cm away. The
cables must be no longer than 10 m and must be shielded.
For optimal results, we recommend that you place it high up and at least 1 meter away from all metallic objects if
possible (see diagrams below). Note that the antenna is integrated into the housing.
2m
Opening slot