Before each fault elimination:
switch off device
wait for standstill of the beater
pull out power plug
After each fault clearance, put into operation and recheck all security installations.
Problem
Possible cause
Remedy
Motor does not start.
No power supply (power failure)
Mains cable defective.
Motor or switch defect
Check fuses (16 A)
Exchange defect cable, respectively check ex-
tension cable, (by electrician)
Never use defect lead
To correct the problem, refer to the manufacturer
or other approved service centre.
Unusual vibrations
Beater defective.
Chuck defective.
Non-intended material to be mixed.
Replace the beater.
To correct the problem, refer to the manufacturer
or other approved service centre.
Incorrect processing. Follow the processing in-
structions from the supplier.
Device starts but blocks under
slight load and cuts off auto-
matically.
Extension cable too long, or cross-
section too small.
Socket too far away from main connec-
tion, and cross-section of connection
lead too small.
Extension cable at least 1,5 mm2 , maximum 25
m long.
Cross- section of at least 2,5 mm2 in longer
cables.
T
T
e
e
c
c
h
h
n
n
i
i
c
c
a
a
l
l
d
d
a
a
t
t
a
a
Type / Model
RL 1600 G
Year of construction
See last page
Motor power P
1
1600 W
Motor
AC-motor 230 V ~ 50 Hz
Speed (counter-rotating) n
0
with speed control
Mortar beater: 290 - 480 min
-1
(clockwise)
Disc beater: 380 - 620 min
-1
(anticlockwise)
Beater diameter (Mortar beater / Disc beater)
140 mm / 114 mm
Beater chuck
M18
Beater length
approx. 570 mm
Hand-arm-vibration on the handle
a
h
= < 2.291 m/s²
Measuring uncerntainty K
1.5 m/s²
Volume of the material to be mixed
approx. 90 litres
Weight
approx. 5.5 kg
Measured sound power level L
WA
98.7 dB (A)
Measured sound pressure level L
PA
87.7 dB (A)
Measuring uncerntainty K
3 dB (A)
Safety class
II
/
double insulated
Protection class
IP20