background image

Electric lock mode setting 

When the 

Camera Module 

is in Programming 

mode: 

1. 

Press  Key  A,  the 

Unlock  Indicator 

will

 

turn  on  with  the  warning  sound  of  a  long 
Beep followed by a short Beep 

2. 

Press Key A again to select mode 

a. Mode = 0 (default) 

Normally  Open

:  The 

Status  indicator 

blinks  once  with  the  warning  sound  of  a 
single long Beep 

b. Mode = 1 

Normally  Closed

:  The 

Status  indicator 

blinks  twice  with  the  warning  sound  of  a 
long Beep followed by a short Beep. 

 

 

 

Lock time delay setting 

When the 

Camera Module 

is in programming 

mode: 

1. 

Press Key A. The 

Unlock indicator 

turns 

on with the warning sound of a long Beep 
followed by a short Beep. 

2. 

Press  Key  B  and  hold  for  desired  lock 
opening time. 

The 

Unlocking Time 

delay is indicated by the 

number  of  times  that  the 

Status  indicator 

blinks  (set  in  seconds).  For  example:  The 

Status indicator 

blinks

 

four times, that means 

the unlocking time is 4 seconds. 

 

 

 

 

 

 

 

 

Sound setting 

When the 

Camera Module 

is in programming 

mode: 

1. 

Press  and  hold  Key  A  for  3  seconds  to 
enter the 

Sound Option Mode

, the 

Status 

indicator 

will

 

turn  on  and  the  current 

sound will play. 

2. 

Press Key A again to play the next tune 

3. 

Press Key B to exit. 

 

 

 

Sound volume setting 

When the 

Camera Module 

is in programming 

mode: 

1. 

Press  Key  B  to  enter 

Tune  Volume  

Setting

, the 

Talk indicator 

will

 

turn on and 

play the sound at the current volume. 

2. 

Press  Key  A  to  increase/decrease  the 
volume (loop setting) 

3. 

Press Key B to exit. 

 

 

 

Talk volume setting 

1. 

During  the  conversation,  press  and  hold 
Key  B  for  3  seconds  to  enter  the 

Talk 

Volume Setting

The 

Talk indicator will 

turn on with a long 

Beep followed by a short Beep. 

2. 

Press  Key  A  to  increase/decrease  the 
volume (loop setting). 

3. 

Press Key B to exit. 

 

 

 

 

 

Summary of Contents for A1702

Page 1: ...2 Wire Digital Video System Installation Manual ...

Page 2: ...d to a single call button Maximum of 4 monitors can be connected in daisy chain configuration Maximum of 8 monitors can be connected to a single A2200 in distributor mode DIP switch 1 OFF Maximum of 4 A2200 units can be connected to single A2200 in raiser mode DIP switch 1 ON Cable distances CAT5e UTP cores twisted by colour code Twist the cores of CAT5e UTP as shown in the image White with colour...

Page 3: ... switches for system configuration 2 JP LK Jumper for setting state of the NO contact 3 CN KMB Digital display module connection port 4 CN T COIL Not in use 5 BUS L1 L2 bus line connecting to terminal BUS DS on the power supply 6 CN LK 12V 12VDC power output LK Power ground LK Common contact of the relay NO Normally open closed contact use JP LK jumper to set EB Exit button connection port EB Exit...

Page 4: ...y and 1 is the setting for five seconds delay DIP switch 6 is for activating keys A and B which are used for programming camera module functions see next section The default setting for this DIP switch is 0 Video module functions and programming Restore factory settings Warning All settings will be deleted if the Restore Factory Setting is activated When the Camera Module is in standby short out t...

Page 5: ...imes that the Status indicator blinks set in seconds For example The Status indicator blinks four times that means the unlocking time is 4 seconds Sound setting When the Camera Module is in programming mode 1 Press and hold Key A for 3 seconds to enter the Sound Option Mode the Status indicator will turn on and the current sound will play 2 Press Key A again to play the next tune 3 Press Key B to ...

Page 6: ...mally closed mode 2 3 Normally open mode Fail Locked Fail Unlocked Electric lock external power 1 Open contact output is limited to 24Vdc and a maximum current of 1000mA 2 The jumper must be taken off before connecting 3 Set lock type using touch keys A and B see module programming Fail Locked Mode 0 default Fail Unlocked Mode 1 ...

Page 7: ... for programming user pin codes and other functions and features Use to confirm and to cancel If no button is pressed for 10 seconds keypad will automatically exit programming mode Example of adding new user code 2525 Enter Master Code 1234 Enter Location Code C 20 Enter user PIN value V 2525 Press to finish and exit Combination example 1234 20 2525 Press 2525 to test and release the lock Programm...

Page 8: ...TE tag to card reader 2 Present user tag you wish to delete to card reader Or use keypad to enter room number you wish to remove all user tags from and press to confirm 3 Repeat steps 2 to remove more user tags 4 Present MASTER CARD DELETE tag to finish Delete all users and tags 1 In standby mode present MASTER CARD DELETE tag to card reader wait for double beep 2 Present MASTER CARD ADD tag to ca...

Page 9: ...n B on the speech module for 10 seconds and release when you hear the beep and all lights turn on 4 Wait until you hear another beep and all lights turn off 5 Restore is now complete Restore to factory default Caution When using this procedure all information will be lost and modules restored to default factory settings You can reset Master PIN code without losing all information by following back...

Page 10: ...System layout Distributor mode ...

Page 11: ......

Page 12: ...System layout Riser mode ...

Page 13: ......

Page 14: ......

Reviews: