ATIGO A1702 Installation Manual Download Page 8

Digital display module A3203 

 

 

 

Digital display module is also design as a 
proximity card reader with up to 320 user tags 
capacity. Reader supports 125KHz and 
13.56MHz unencrypted RFID tags 

Use supplied master tags to add and delete 
user tags. 

 

Programming Tags 

 

Add user tags 

1. 

In standby mode present  
MASTER CARD

 

ADD

 

tag to card 

reader 

2. 

Use keypad to enter room number 
new user tag need to be associated 
with and press 

to confirm. 

3. 

Tap to add all user tags associated 
with selected room. 

4. 

Repeat steps 2 and 3 to add more 
user tags 

5. 

Present MASTER CARD

 

ADD

 

tag 

to finish. 
 

 

 

 

 

Delete specific user tags 

1. 

In standby mode present  

MASTER CARD

 

DELETE

 

tag to 

card reader. 

2. 

Present user tag you wish to delete 
to card reader. 
Or use keypad to enter room 
number you wish to remove all user 
tags from and press 

to confirm. 

3. 

Repeat steps 2 to remove more 
user tags. 

4. 

Present MASTER CARD

 

DELETE

 

tag to finish. 
 
 

Delete all users and tags 

1. 

In standby mode present  
MASTER CARD

 

DELETE

 

tag to 

card reader, wait for double beep. 

2. 

Present MASTER CARD

 

ADD

 

tag 

to card reader, wait for double 
beep. 

3. 

Once more present  
MASTER CARD

 

ADD

 

tag to card 

reader, wait for single beep. 

4. 

Wait 10 seconds for reader to 
return to standby mode. 
 

Program new MASTER CARD tags 

1. 

Make sure all modules are 
connected and powered up. 

2. 

Link together wires EB+ and EB 

– 

on audio/video module and wait for 
a beep 

3. 

Switch ON and OFF DIP switch 4, 
four times, wait for double beep. 

4. 

Wait 10 seconds for reader to 
return to standby mode. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for A1702

Page 1: ...2 Wire Digital Video System Installation Manual ...

Page 2: ...d to a single call button Maximum of 4 monitors can be connected in daisy chain configuration Maximum of 8 monitors can be connected to a single A2200 in distributor mode DIP switch 1 OFF Maximum of 4 A2200 units can be connected to single A2200 in raiser mode DIP switch 1 ON Cable distances CAT5e UTP cores twisted by colour code Twist the cores of CAT5e UTP as shown in the image White with colour...

Page 3: ... switches for system configuration 2 JP LK Jumper for setting state of the NO contact 3 CN KMB Digital display module connection port 4 CN T COIL Not in use 5 BUS L1 L2 bus line connecting to terminal BUS DS on the power supply 6 CN LK 12V 12VDC power output LK Power ground LK Common contact of the relay NO Normally open closed contact use JP LK jumper to set EB Exit button connection port EB Exit...

Page 4: ...y and 1 is the setting for five seconds delay DIP switch 6 is for activating keys A and B which are used for programming camera module functions see next section The default setting for this DIP switch is 0 Video module functions and programming Restore factory settings Warning All settings will be deleted if the Restore Factory Setting is activated When the Camera Module is in standby short out t...

Page 5: ...imes that the Status indicator blinks set in seconds For example The Status indicator blinks four times that means the unlocking time is 4 seconds Sound setting When the Camera Module is in programming mode 1 Press and hold Key A for 3 seconds to enter the Sound Option Mode the Status indicator will turn on and the current sound will play 2 Press Key A again to play the next tune 3 Press Key B to ...

Page 6: ...mally closed mode 2 3 Normally open mode Fail Locked Fail Unlocked Electric lock external power 1 Open contact output is limited to 24Vdc and a maximum current of 1000mA 2 The jumper must be taken off before connecting 3 Set lock type using touch keys A and B see module programming Fail Locked Mode 0 default Fail Unlocked Mode 1 ...

Page 7: ... for programming user pin codes and other functions and features Use to confirm and to cancel If no button is pressed for 10 seconds keypad will automatically exit programming mode Example of adding new user code 2525 Enter Master Code 1234 Enter Location Code C 20 Enter user PIN value V 2525 Press to finish and exit Combination example 1234 20 2525 Press 2525 to test and release the lock Programm...

Page 8: ...TE tag to card reader 2 Present user tag you wish to delete to card reader Or use keypad to enter room number you wish to remove all user tags from and press to confirm 3 Repeat steps 2 to remove more user tags 4 Present MASTER CARD DELETE tag to finish Delete all users and tags 1 In standby mode present MASTER CARD DELETE tag to card reader wait for double beep 2 Present MASTER CARD ADD tag to ca...

Page 9: ...n B on the speech module for 10 seconds and release when you hear the beep and all lights turn on 4 Wait until you hear another beep and all lights turn off 5 Restore is now complete Restore to factory default Caution When using this procedure all information will be lost and modules restored to default factory settings You can reset Master PIN code without losing all information by following back...

Page 10: ...System layout Distributor mode ...

Page 11: ......

Page 12: ...System layout Riser mode ...

Page 13: ......

Page 14: ......

Reviews: