INSTALLATION INSTRUCTIONS

 

GENERAL INFORMATION AND FEATURES

 

 

210-0197_Libretto_TX_ATI_2020-02_ATI-eng 

ed. 2020-02 

 

11 LOCAL REGULATIONS, AND INSTALLATION OF SAFETY 

 

LOCAL REGULATIONS 

In the installation the local regulations must be observed regarding: 

 

Fire fighters 

 

Gas Company 

 

power Company 

 

Office hygiene and health 

 SAFETY RULES

 

 

Do not perform any cleaning or maintenance work without turning off the water heater and interrupting power 
supply. 

 

E 'absolutely forbidden to operate the water heater with protection of electrical parts or disassembled safety 
equipment excluded. E 'absolutely it is forbidden to remove or tamper with safety devices. 

 

In case of failure and / or malfunction switch off the appliance, close the gas valve and not groped to repair it but 
contact an authorized service center. 

 

In case of fire should be used in powder extinguishants: not direct jets of water directly against the heaters as they 
may cause short circuits. 

 

Apply tools and / or equipment manuals and / or electrical proper use, they are in good condition and used 
properly. 

 

Make sure that ladders and / or any rolling ladders are positioned securely, that are appropriate and that the steps 
are intact and not slippery, that they are not moved when someone climbs them and ensure someone supervises. 

 INSTALLATION INSTRUCTIONS 

 

Make sure, for installation and maintenance work at height (generally with higher altitude to two meters), which 
are used in scaffolding standards and the space below is free during the eventual fall of tools and objects. 

 

Make sure that, in case of installation and maintenance, the workplace has adequate hygienic conditions with 
regard to lighting, aeration and solidity. 

 

Wear during installation and maintenance, clothing and adequate personal protective equipment. 

 

Do not take any action without a prior assessment of the absence of gas leaks using special detector. 

 

The installer must be enabled in the installation of heating equipment according to the law n. 46 of 05/05/1990 and 
after work must issue the CONFORMITY 'DECLARATION to the customer. 

 

The appliance must be connected to a hot water distribution network compatible with its performance and its 
power. Make sure the installation site and any systems to which it must connect the device comply with the 
current regulations. 

 

Before each installation, maintenance or repair, remove the power supply. Protecting tubes and external 
connection cables in such a way as to prevent them from being damaged. 

 

The device is to be installed on the floor surface, leaving a suitable distance from the side walls to allow the gas 
and water connections, as well as any maintenance interventions. Furthermore, the appliance must be installed on 
a solid floor, not subject to vibration, not uneven or non-planar. 

 

The operations inside the unit must be performed with caution so as to avoid abrupt contact with sharp parts. 

 

Do not take any action without a prior assessment of the absence of an open flame or ignition sources. 

 

If you detect a smell of burning, see the smoke out exit from the apparatus, or is felt strong smell of gas, remove 
the power supply, close the gas valve, open the windows and notify the authorized service centers nearest 

IN ANY SITUATION AND 'WELL ALWAYS REMEMBER THAT COMMON SENSE  

IS THE BEST SECURITY AGAINST ANY AND / OR INJURY.

 

 

Summary of Contents for TX160

Page 1: ...TX160 TX220 TX300 TX400 TX600 TX800 ENG Manual installation use and maintenance Original instructions Read and follow these instructions before installing the unit Always keep on hand this manual duri...

Page 2: ...FUNCTIONAL AND CONSTRUCTION 6 9 EQUIPMENT COMPONENTS 7 10 WIRING 8 11 LOCAL REGULATIONS AND INSTALLATION OF SAFETY 9 12 INSTALLATION 10 13 POSITIONING APPARATUS 10 14 BREAK WIND INSTALLATION DRAW 11 1...

Page 3: ...by unsupervised children If the appliance should be sold or transferred to another owner ensure that this booklet accompanies the same so that they can be consulted by the new owner and or installer n...

Page 4: ...parts 1 and 2 are present and that they are not damaged during transport 1 2 TX160 cm 58 x 58 x 185 131 kg cm 46 x 46 x 23 5 kg TX220 cm 78 x 78 x 141 184 kg cm 68 x 68 x 25 6 kg TX300 cm 78 x 78 x 17...

Page 5: ...8 1 9 1 9 2 1 2 2 NOx emission value mg kWh 54 26 29 36 35 37 Max water pressure kPa 600 600 600 600 600 600 empty weight Kg 118 173 206 243 246 301 full weight Kg 278 393 506 643 831 1 041 electrical...

Page 6: ...TR I2H G20 20 mbar 8 DESCRIPTION FUNCTIONAL AND CONSTRUCTION The function of this device is to generate hot water through the heat exchange between the combustion products of the burner and the water...

Page 7: ...threshold the safety thermostat comes into operation by blocking the appliance To unlock it unscrew the lid and hold the button below F THERMOSTAT Used to adjust the internal temperature of the tank G...

Page 8: ...10 WIRING L Line N Neutral THE Switch SB red lock lamp RESET reset button T Control thermostat SA Power indicator VG1 valve GAS TS Water Safety thermostat TF Flue safety thermostat ACC Ignition elect...

Page 9: ...n and maintenance the workplace has adequate hygienic conditions with regard to lighting aeration and solidity Wear during installation and maintenance clothing and adequate personal protective equipm...

Page 10: ...e possibly damaged with tape or clamps If the power cord is damaged it must be replaced by service agent or a similarly qualified person in order to avoid a hazard Incorrect installation can cause dam...

Page 11: ...pliance so as not to obstruct the path of the fumes Mod 160 Mod 220 300 400 600 800 Make sure that during operation or transportation the B flue safety thermostat bulb has not been damaged or moved fr...

Page 12: ...to remove any impurities such as sand gravel mud etc G check valve H stopcock cold input I stopcock hot output SAFETY VALVE l Appliance is equipped with a safety valve against excess pressure The com...

Page 13: ...TX160 TX220 TX300 TX400 TX600 TX800 inlet pressure mbar 37 0 pressure regulating here I m injector pressure mbar 25 5 25 5 27 5 25 0 27 5 27 5 N injectors 2 x 1 35 3 x 1 55 3 x 1 60 3 x 1 60 3 x 1 65...

Page 14: ...to the specified value through the REG screw on the gas valve To check the value you can use the outlet pressure of P OUT 8 Stick the label contained in the kit to indicate the new type of gas supply...

Page 15: ...provide a disconnect device not supplied with an opening distance of the contacts that allows complete disconnection in the conditions dictated by the overvoltage category III LINE AND NEUTRAL PLUG TO...

Page 16: ...iance is sold or transferred to another owner ensure that this booklet accompanies the same so that they can be consulted by the new owner and or installer Do not place any kind on the subject To get...

Page 17: ...the safety and prolong its life you should have it checked at least once a year by an authorized service center which will act as follows replacing the magnesium anode internal inspection of the boile...

Page 18: ...th from uncontrolled waste disposal the user is encouraged to separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users...

Page 19: ...INSTRUCTIONS FOR THE USER 210 0197_Libretto_TX_ATI_2020 02_ATI eng 19 ed 2020 02...

Page 20: ...210 0197_Libretto_TX_ATI_2020 02_ATI eng 20 ed 2020 02 ATI DI MARIANI SRL Via E Mattei 461 Zona Ind No 4 Torre del Moro 47522 Cesena FC ITALY Tel 0547 609711 www atimariani it info atimariani it...

Reviews: