Flexdeburr Installation and Operation Manual
Document: 9610-50-1007-11
Pinnacle Park
•
1031 Goodworth Drive
•
Apex, NC 27539
•
Tel: 919.772.0115
•
Fax: 919.772.8259
•
www.ati-ia.com
•
Email: [email protected]
16
All noise emission measurements were taken under no load idle conditions without a cutting
tool. Because the working environment is unknown, it is impossible to predict the noise that will
occur during a deburring operation.
Each RC deburring tool receives a thorough test procedure before it is shipped.
Below are measured forces relative to applied compliance (centering) air pressure.
Measurements may vary from one product to another, and should only be treated as nominal.
RC-300/340 Series Radial Contact Force
0
5
10
15
20
25
30
35
40
45
1.0
2.0
3.0
4.0
Centering Air Pressure (bar)
Ra
d
ial
F
o
rc
e
(
N
)
RC-300/340 Series Radial Contact Force
0
1
2
3
4
5
6
7
8
9
10
10
20
30
40
50
60
70
Centering Air Pressure (PSI)
R
a
di
a
l F
o
rc
e
(
lbf
)
Figure 3.1—RC-300/340 Series Radial Compliance Force Curves
(Measured at the Spindle Tip)