ATI Audio DDA-106 SERIES 2 Operating And Maintenance Manual Download Page 5

 

 

 

ATI Audio Inc.      

     Tel: 856-626-3480      

      Fax: 856-504-0220      

     [email protected]      

      www.

 

 

audio.com 

 

OUTPUT DRIVERS

 

 

DDA-106XLR  units  are  equipped  with  balanced,  110-ohm,  transformer  coupled 
outputs  and  XLR  type  connectors.  DDA-106BNC  units  use  the  alternative  75-
ohm  unbalanced  outputs  to  BNC  coax  connectors.  The  XLR  outputs  are  in  full 
compliance  with  specification  AES3-1992  and  the  BNC  outputs  are  in 
accordance  with  the  recommendations  of  AES-3id-1995.  XLR  outputs  are 
transformer coupled for ground isolation.

 

 

POWER SUPPLY 

 

Power transformer primary windings are paralleled for 115VAC or wired in series 
for 230VAC. Internal jumpers allow field modification if necessary. See below for 
voltage conversion instructions. 

 

INSTALLATION 

 

LOCATION 

 

To avoid addition of  jitter (timing variations) to the digital bitstream, which  could 
cause  noise  and  distortion  in  the  recovered  audio,  avoid  locating  the  DDA  in 
close proximity to a high energy, high frequency switching type power supply or a 
power  amplifier  that  utilizes  a  switching  supply.  If  possible,  do  not  power  both 
devices from the same AC power line. 

 

Expensive components start to die at internal temperatures above 70°C (158°F). 
We  recommend  that  you  maintain  rack  temperatures  below  50°C  (122°F)  to 
prevent excessive internal temperature buildup. This is another good reason not 
to mount the DDA directly above that 500W power amplifier. 

 
 

POWER 

 

If it is necessary to convert a unit wired for 115VAC to 230VAC operation, unplug 
the  unit  from  the  power  source,  remove  the  cover  mounting  screws  and  locate 
the  jumpers  next  to  the  power  transformer.  Clip  the  jumpers  1-2  and  3-

4  (don’t 

unsolder),  jumper  from  2-3  carefully  soldering  together  the  free  ends  of  2-3 
previously clipped. This procedure is recommended to avoid soldering damage to 
the multi-layer PC board. 

 
 

WIRING 

 

XLR types require special controlled impedance, 110 ohm, low loss, foil shielded, 
twisted pair cables. Standard audio cable is not recommended except for runs of 
only a few feet. Belden and  most other cable manufacturers offer special digital 
audio  cabling  for  this  application.  With  equalization,  cable  runs  of  300  meters 
(about  1000  feet)  should  be  achievable.  BNC  types  use  75-ohm  coax  (RG59). 
Select a cable for losses less than 20dB at 12MHz (for data rates up to 96kHz) at 
the  maximum  distance  you  require.  Runs  up  to  1000  meters  should  be  readily 
achievable with low loss coax. 

Summary of Contents for DDA-106 SERIES 2

Page 1: ...dio Inc Tel 856 626 3480 Fax 856 504 0220 sales atiaudio com www audio com DDA 106 SERIES 2 192kHz AES EBU DIGITAL AUDIO DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL Copyright 2011 ATI Aud...

Page 2: ...ts contain a unique automatic equalization function that can adjust for extremely long input lines Equalization works independently for each input A Front Panel Lock feature protects all your settings...

Page 3: ...equalization should only be necessary for extremely long input cable lengths and should only be used if proven to be necessary Automatic equalization is enabled by pressing the front panel button labe...

Page 4: ...tes input data is present and acceptable ENABLED indicates equalization is applied Press the INPUT EQ button to enable automatic equalization Input Select Selects either Input 1 or Input 2 Front Panel...

Page 5: ...Expensive components start to die at internal temperatures above 70 C 158 F We recommend that you maintain rack temperatures below 50 C 122 F to prevent excessive internal temperature buildup This is...

Page 6: ...r Inputs 1 or Input 2 Sample Rates Accepts 27kHz to 192kHz Clock With re clocking on regenerated from input signal clock jitter 300 picoseconds peak to peak at 96kHz sample rate With re clocking off i...

Page 7: ...uct that has been discontinued from its product line with a new product of comparable value and function This warranty shall be void in the event a covered product has been damaged or failure is cause...

Reviews: