FRONT PANEL DISPLAYS AND SWITCHES

 

 

Input Termination 
Indicates  whether  the  input  termination  is  Off  or  On.  Press  the  INPUT  TERM 
button to toggle the setting. 
 
Input Sample Rate 
Indicates the sample rate of the input signal from 32 through 192 kHz. 
 
Word Length 
Indicates the Word Length of the input signal from 16 through 24 bit. 
 
Digital Errors 
Indicates  four  main  error  conditions  encountered  in  digital  signals  as  an  aid  to 
troubleshooting, 
 
Re-Clocking 
Indicates Input Re-Clocking On or Off. Press the RE-CLOCKING button to toggle 
the setting. 
 
Mode 
Indicates whether input signal is Pro or Consumer mode. 
 
Input EQ 
Enables  automatic  input  equalization.  LOCKED  indicates  input  data  is  present 
and  acceptable.  ENABLED  indicates  equalization  is  applied.  Press  the  INPUT 
EQ button to enable automatic equalization. 
 
Input Select 
Selects either Input 1 or Input 2. 
 
Front Panel Lock 
Press  and  hold  the  FRONT  PANEL  LOCK  button  to  lock  all  the  front  panel 
controls. Press and hold again to unlock. 

 
 

TRANSMITTERS

 

 

The  Frame  sync  (FSYNC),  Serial  Clock  (SCK),  Serial  audio  data  (SDATA), 
Channel status (C), User channel data (U), and data Validity information (VERF) 
are passed directly to the transmitters for reformatting into the AES/EBU  output 
data  stream.  The  transmitters  are  capable  of  operation  from  27  to  192  kHz 
equivalent sample rates. The transmitters operate  in a transparent  mode, which 
allows the transmitter block structure (Channel Status, User  and Validity  bits) to 
be  slaved  to  the  block  structure  of  the  receiver.  In  the  transparent  mode  the 
propagation  delay  of  data  is  less  than  25  nanoseconds  even  at  the  lowest 
sample rate. 

Summary of Contents for DDA-106 SERIES 2

Page 1: ...dio Inc Tel 856 626 3480 Fax 856 504 0220 sales atiaudio com www audio com DDA 106 SERIES 2 192kHz AES EBU DIGITAL AUDIO DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL Copyright 2011 ATI Aud...

Page 2: ...ts contain a unique automatic equalization function that can adjust for extremely long input lines Equalization works independently for each input A Front Panel Lock feature protects all your settings...

Page 3: ...equalization should only be necessary for extremely long input cable lengths and should only be used if proven to be necessary Automatic equalization is enabled by pressing the front panel button labe...

Page 4: ...tes input data is present and acceptable ENABLED indicates equalization is applied Press the INPUT EQ button to enable automatic equalization Input Select Selects either Input 1 or Input 2 Front Panel...

Page 5: ...Expensive components start to die at internal temperatures above 70 C 158 F We recommend that you maintain rack temperatures below 50 C 122 F to prevent excessive internal temperature buildup This is...

Page 6: ...r Inputs 1 or Input 2 Sample Rates Accepts 27kHz to 192kHz Clock With re clocking on regenerated from input signal clock jitter 300 picoseconds peak to peak at 96kHz sample rate With re clocking off i...

Page 7: ...uct that has been discontinued from its product line with a new product of comparable value and function This warranty shall be void in the event a covered product has been damaged or failure is cause...