background image

 

 

33 

 

APA-303 TR

APA-503 TR

APA-303 TRL

APA-503 TRL

APA-753 TRL

APA-753 TR

APA-104 TR

Capacity

VA / Watt

3kVA/1875W

5kVA/3125W

3kVA/1875W

5kVA/3125W

7.5kVA/4688W

7.5kVA/4688W

10kVA/6250W

Acceptable Voltage Range

Frequency

Boost Transfer

Boost Return

Buck Transfer

Buck Return

Low Voltage Transfer

Low Voltage Return

High Voltage Transfer

High Voltage Return 

Line Mode

Battery Mode

Line Mode

Battery Mode

Line Mode

Battery Mode

Line Mode

Battery Mode

36Vdc

48Vdc

36Vdc

48Vdc

48Vdc

48Vdc

48Vdc

7Ah

8.5Ah

N/A

N/A

N/A

7Ah

8.5Ah

6pcs

8pcs

N/A

N/A

N/A

16pcs

16pcs

440*132*465

440*132*620

36.6

50.2

25.5

31.4

36.4

31.4

36.4

Net Weight (Kg)

NEMA Outlets

8

(110/115/120Vac)

IEC Outlets

10

10

(220/230/240Vac)

Beeping every second

Typical

Voltage

Type

Quantity

Backup Time

Battery Mode

Low Battery

UPS Fault

Overload

Beeping twice per second

150Vac ± 2% ; 300Vac ± 2%

300Vac ± 2%

145Vac ± 2% ; 290Vac ± 2%

290Vac ± 2%

MODEL NAME

Voltage

110/115/120Vac or 220/230/240Vac re-settable via LCD panel

Voltage Regulation

± 15%

< 3% RMS for entire battery voltage range

Nominal Voltage

Voltage Range

45Hz ~ 70Hz Auto-sensing

Efficiency

Overload Protection

Short Circuit Protection

Frequency Regulation

Power Factor

Wave Form

Recharging Current

LCD Display

LED

Cold Start

Yes

< 4 ms

UPS status, I/P&O/P Voltage/Frequency, Load level, Battery voltage &level, Temperature, Model

Normal(Green), Warning (Amber), Fault (Red)

Beeping every 4 seconds

Beeping continuously

> 3 min

0.1C ~ 0.3C

Synchronize to AC main

50Hz or 60Hz ± 0.1Hz

0.625

Pure sine wave

> 80%

> 110%, then buzzer alarm and amber LED blink continuously

110%~150% : 30 sec, >150% : 200ms, then UPS shutdown

Circuit breaker

Electronic circuit

205.5Vac ± 2% 

132Vac ± 2% ; 264.5Vac ± 2%  

264.5Vac ± 2%  

127Vac ± 2% ; 254.5Vac ± 2% 

254.5Vac ± 2% 

85Vac ± 2% ; 170Vac ± 2%

170Vac ± 2%

90Vac ± 2% ; 180Vac ± 2%

180Vac ± 2%

Rack Battery Bank APA BTR16:for 16 pcs 12V/7Ah or 16pcs 12V/9Ah.Dimension :W*H*D=440 *132 *465 mm

7.5-10k VA conn ect to an external battery bank

All specification s mention ed abo ve are sub ject to chang e withou t prior no tice

RS232

8

8+1 terminal block

10+1 terminal block

440*132*465

4+1 terminal block

5+1 terminal block

0-40

(32-104

)

0-95% (non-condensing)

< 55dBA

Various Comb. of RS232, SNMP, USB, Dry Contact, AS400, Enable at the same time

Standard

Multi-Interfaces Card(Option)

Operation Temperature

Relative Humidity

Audible Noise(At 1M)

Safety Standard

EN62040-1-1

EMC

EN62040-2

Marks

CE

Dimensions(W*H*D)mm

APA 3KVA/5KVA/7KVA/10KVA Tower & Rack convertible

Output

DC Start

T ransfer time

Battery

Control panel

Safety conformance

Physical

Environment

Comm unication interfaces

Audible alarm

Tower & Rack convertible

(long backup model)

Tower & Rack convertible

Tower & Rack convertible

110/115/120 Vac or 220/230/240Vac

220/230/240Vac

85Vac ~ 150Vac or 170Vac ~ 300Vac

170Vac ~ 300Vac

97.8Vac ± 2% ; 195.5Vac ± 2%

195.5Vac ± 2%

Inpu t

Mod e Type

102.8Vac ± 2% ; 205.5Vac ± 2% 

Summary of Contents for APA-103T

Page 1: ...USER S MANUAL Line interactive UPS 650VA 1KVA 1 5KVA 2KVA 3KVA TR 5KVA TR 7 5KVA TR PM 10KVA TR PM...

Page 2: ...NTENTS 1 INTRODUCTION 2 2 SAFTY INSTRUCTION 3 3 SYSTEM DESCRIPTION 6 4 OUTLINE DESCRIPTION 8 5 CABLE CONNECTION 21 6 OPERATION 22 7 TROUBLE SHOOTING GUIDE 27 8 OPERATION MODES OF THE UPS 29 9 COMPUTER...

Page 3: ...e UPS more compact and less noisy To choose the UPS as your equipment protector is a wise investment because it supplies reliable pure and stable power at affordable price 1 2 Key features Line intera...

Page 4: ...or long period the battery must be charged once every 60 days 5 Retain the load within the rating of the UPS to prevent faults 6 Handle unusual events according to the trouble shooting guide 7 Keep th...

Page 5: ...op of the UPS 5 Allow a minimum distance of 10 cm in the rear and two sides of the UPS for ventilation 6 Keep the UPS far away from heat emitting sources 7 Do not expose it to corrosive gas 8 Ambient...

Page 6: ...e mains power supply building wiring socket outlet components inside the UPS system are still connected to the battery and are still electrically live and dangerous Before carrying out any kind of ser...

Page 7: ...same number and same type of batteries 5 Do not attempt to dispose of batteries by burning them This could cause battery explosion 6 Do not open or destroy batteries Escaping electrolyte can cause inj...

Page 8: ...twice Switch Off Press both Key 2 and Key 4 Simutaneouly for 3 secnonds until UPS beeps for twice Mute When UPS is on and is on DC mode UPS will beep every 4 seconds Press both Key 2 and Key 3 simulta...

Page 9: ...8 4 OUTLINE 4 1 Description 650VA Tower Case...

Page 10: ...9 1KVA 1 5K 2KVA Tower Case...

Page 11: ...10 1KVA 1 5KVA 2VA Rack Tower Convertible Case...

Page 12: ...11 3KVA Rack Tower Convertible Case...

Page 13: ...12 5KVA Rack Tower Convertible Case...

Page 14: ...13 7 5KVA 10KVA Rack Tower Convertible Case...

Page 15: ...14 1KVA 1 5KVA Rack 1U Case...

Page 16: ...15 4 2 Back View Description 650VA Tower Case 1 USB Port 5 Fan 2 Fax Modem Surge Protection Option 6 Breaker 3 Remote Control Detachable LCD Panel Option 7 Input Socket 4 Output Socket NEMA or IEC...

Page 17: ...KVA 2KVA Tower Case 1 SNMP Interface Slot Option 5 External Battery Socket L 2 Fax Modem Surge Protection Option 6 Breaker 3 Remote Control Detachable LCD Panel Option 7 Input Socket 4 Output Socket N...

Page 18: ...Interface Port USB Port for Multi card Option 6 Fan 2 SNMP Interface Slot Option 7 External Battery Socket L 3 Fax Modem Surge Protection Option 8 Breaker 4 Remote Control Detachable LCD Panel Option...

Page 19: ...ace Port USB Port for Multi card Option 6 Fan 2 SNMP Interface Slot Option 7 External Battery Socket L 3 Fax Modem Surge Protection Option 8 Breaker 4 Remote Control Detachable LCD Panel Option 9 Inpu...

Page 20: ...ce Port USB Port for Multi card Option 6 Fan 2 SNMP Interface Slot Option 7 External Battery Socket L 3 Fax Modem Surge Protection Option 8 Breaker 4 Remote Control Detachable LCD Panel Option 9 Termi...

Page 21: ...wer Convertible Case 1 RS 232 Interface Port USB Port for Multi card Option 5 Fan 2 SNMP Interface Slot Option 6 Breaker 3 Remote Control Detachable LCD Panel Option 7 Terminal Block 4 Output Socket N...

Page 22: ...21 1KVA 1 5KVA Rack 1U Case 1 RS 232 Interface Port USB Port for Multi card Option 4 Breaker 2 SNMP Interface Slot Option 5 Input Socket 3 Output Socket NEMA or IEC 6 EPO Option...

Page 23: ...hould you find signs of damage Please keep the packaging in a safe place for future use 4 Please ensure that the incoming feeder is isolated and secured to prevent it from being switched back on again...

Page 24: ...n the OFF position 4 Check if input voltage meets the UPS rating required 6 2 Operation Procedure Please follow the instructions below for the UPS operation 1 Once the AC source is connected the LCD D...

Page 25: ...CD display illuminates and Normal LED is blinking until AC source is disconnected 6 3 Storage Instruction Disconnect input power in rear panel if you will not use it for long period If the UPS is stor...

Page 26: ...25 1 Rated Spec Menu 2 Status Menu 3 Voltage Menu 4 Frequency Menu...

Page 27: ...26 5 Battery Status Menu 6 Output Power Menu 7 Temperature Menu 8 History Record Menu...

Page 28: ...up to indicate the output voltage or frequency newly selected C Use 2 Up or 3 Down key to adjust the output voltage 220V 230V and 240V are available for 220V system 100V 110V 115V and 120V are availab...

Page 29: ...eplace the fan 2 Restart UPS 2 AC utility power is normal but UPS is overloaded Warning LED lights up and buzzer beeps per second Overload 100 load 125 Please reduce the critical load to 100 3 AC util...

Page 30: ...extend backup time 2 Please check the rated input or connected line 6 AC utility fails UPS is in battery backup mode Buzzer alarm beeps every second Battery power is approaching low level UPS will shu...

Page 31: ...AC utility input and passes through static switch to support power to load The battery charging voltage comes from AC utility input and converted by AC DC charger to support battery charging power 8...

Page 32: ...serial ports By this method the user is able to monitor the following parameters Input Voltage Indicates the present input voltage to the UPS system when AC power is present Output Voltage Indicates...

Page 33: ...er Fault Red Beeping every 4 seconds Beeping every second Beeping continuously 85Vac 150Vac or 170Vac 300Vac 45Hz 70Hz Auto sensing Voltage Regulation Frequency Regulation Overload Protection Short Ci...

Page 34: ...age level Temperature Model Normal Green Warning Amber Fault Red Beepingevery 4 seconds Beepingcontinuously 3 min 0 1C 0 3C Synchronize to AC main 50Hz or 60Hz 0 1Hz 0 625 Pure sine wave 80 110 then b...

Reviews: