33
APA-303 TR
APA-503 TR
APA-303 TRL
APA-503 TRL
APA-753 TRL
APA-753 TR
APA-104 TR
Capacity
VA / Watt
3kVA/1875W
5kVA/3125W
3kVA/1875W
5kVA/3125W
7.5kVA/4688W
7.5kVA/4688W
10kVA/6250W
Acceptable Voltage Range
Frequency
Boost Transfer
Boost Return
Buck Transfer
Buck Return
Low Voltage Transfer
Low Voltage Return
High Voltage Transfer
High Voltage Return
Line Mode
Battery Mode
Line Mode
Battery Mode
Line Mode
Battery Mode
Line Mode
Battery Mode
36Vdc
48Vdc
36Vdc
48Vdc
48Vdc
48Vdc
48Vdc
7Ah
8.5Ah
N/A
N/A
N/A
7Ah
8.5Ah
6pcs
8pcs
N/A
N/A
N/A
16pcs
16pcs
440*132*465
440*132*620
36.6
50.2
25.5
31.4
36.4
31.4
36.4
Net Weight (Kg)
NEMA Outlets
8
(110/115/120Vac)
IEC Outlets
10
10
(220/230/240Vac)
Beeping every second
Typical
Voltage
Type
Quantity
Backup Time
Battery Mode
Low Battery
UPS Fault
Overload
Beeping twice per second
150Vac ± 2% ; 300Vac ± 2%
300Vac ± 2%
145Vac ± 2% ; 290Vac ± 2%
290Vac ± 2%
MODEL NAME
Voltage
110/115/120Vac or 220/230/240Vac re-settable via LCD panel
Voltage Regulation
± 15%
< 3% RMS for entire battery voltage range
Nominal Voltage
Voltage Range
45Hz ~ 70Hz Auto-sensing
Efficiency
Overload Protection
Short Circuit Protection
Frequency Regulation
Power Factor
Wave Form
Recharging Current
LCD Display
LED
Cold Start
Yes
< 4 ms
UPS status, I/P&O/P Voltage/Frequency, Load level, Battery voltage &level, Temperature, Model
Normal(Green), Warning (Amber), Fault (Red)
Beeping every 4 seconds
Beeping continuously
> 3 min
0.1C ~ 0.3C
Synchronize to AC main
50Hz or 60Hz ± 0.1Hz
0.625
Pure sine wave
> 80%
> 110%, then buzzer alarm and amber LED blink continuously
110%~150% : 30 sec, >150% : 200ms, then UPS shutdown
Circuit breaker
Electronic circuit
205.5Vac ± 2%
132Vac ± 2% ; 264.5Vac ± 2%
264.5Vac ± 2%
127Vac ± 2% ; 254.5Vac ± 2%
254.5Vac ± 2%
85Vac ± 2% ; 170Vac ± 2%
170Vac ± 2%
90Vac ± 2% ; 180Vac ± 2%
180Vac ± 2%
Rack Battery Bank APA BTR16:for 16 pcs 12V/7Ah or 16pcs 12V/9Ah.Dimension :W*H*D=440 *132 *465 mm
7.5-10k VA conn ect to an external battery bank
All specification s mention ed abo ve are sub ject to chang e withou t prior no tice
RS232
8
8+1 terminal block
10+1 terminal block
440*132*465
4+1 terminal block
5+1 terminal block
0-40
℃
(32-104
℉
)
0-95% (non-condensing)
< 55dBA
Various Comb. of RS232, SNMP, USB, Dry Contact, AS400, Enable at the same time
Standard
Multi-Interfaces Card(Option)
Operation Temperature
Relative Humidity
Audible Noise(At 1M)
Safety Standard
EN62040-1-1
EMC
EN62040-2
Marks
CE
Dimensions(W*H*D)mm
APA 3KVA/5KVA/7KVA/10KVA Tower & Rack convertible
Output
DC Start
T ransfer time
Battery
Control panel
Safety conformance
Physical
Environment
Comm unication interfaces
Audible alarm
Tower & Rack convertible
(long backup model)
Tower & Rack convertible
Tower & Rack convertible
110/115/120 Vac or 220/230/240Vac
220/230/240Vac
85Vac ~ 150Vac or 170Vac ~ 300Vac
170Vac ~ 300Vac
97.8Vac ± 2% ; 195.5Vac ± 2%
195.5Vac ± 2%
Inpu t
Mod e Type
102.8Vac ± 2% ; 205.5Vac ± 2%
Summary of Contents for APA-103T
Page 9: ...8 4 OUTLINE 4 1 Description 650VA Tower Case...
Page 10: ...9 1KVA 1 5K 2KVA Tower Case...
Page 11: ...10 1KVA 1 5KVA 2VA Rack Tower Convertible Case...
Page 12: ...11 3KVA Rack Tower Convertible Case...
Page 13: ...12 5KVA Rack Tower Convertible Case...
Page 14: ...13 7 5KVA 10KVA Rack Tower Convertible Case...
Page 15: ...14 1KVA 1 5KVA Rack 1U Case...
Page 26: ...25 1 Rated Spec Menu 2 Status Menu 3 Voltage Menu 4 Frequency Menu...
Page 27: ...26 5 Battery Status Menu 6 Output Power Menu 7 Temperature Menu 8 History Record Menu...