32
10. SPECIFICATION
APA 650VA/1KVA/1.5KVA/2KVA
MODEL NAME
APA-650 LED
APA-103T
APA-153T
APA-203T
APA-103U
APA-153U
APA-103TR
APA-153TR
APA-203TR
Capacity
VA / Watt
650VA/406W
1kVA/625W
1.5kVA/938W
2kVA/1250W
1kVA/625W
1.5kVA/938W
1kVA/625W
1.5kVA/938W
2kVA/1250W
Acc eptable Voltage Range
Frequen cy
Boost T ransfer
Boost Return
Buck Transfer
Buck Return
Low Voltage Transfer
Low Voltage Return
High Voltage Transfer
High Voltage Return
Line Mode
Battery Mode
Line Mode
Battery Mode
Line Mode
Battery Mode
Line Mode
Battery Mode
12Vdc
24Vdc
36Vdc
36Vdc
24Vdc
24Vdc
24Vdc
36Vdc
36Vdc
8.5Ah
7Ah
7Ah
8.5Ah
7Ah
7Ah
7Ah
7Ah
8.5Ah
1pce
2pcs
3pcs
3pcs
4pcs
4pcs
2pcs
3pcs
3pcs
> 2m in
0.1C
USB
N/A
115*322*130
145*215*365
5.8
13.2
17.3
20
16.9
19
20.2
24
25.3
Beeping twice per second
6
0-40
℃
(32-104
℉
)
0-95% (non-condensing)
> 110% , then buzz er alarm and am ber LED blin k continuou sly
110% ~150% : 30 sec, >150% : 200ms , t hen UPS shutdown
Circuit breaker
Electronic circuit
Yes
97.8Vac ± 2% ; 195.5Vac ± 2%
102.8Vac ± 2% ; 205.5Vac ± 2%
4
5
> 3 m in
0.1C ~ 0.3C
Various Com b. of RS232, SNMP, USB , Dry Contact, AS400, Enable at t he sam e tim e
RS232
440*88*465
4
6
UPS status, I/P& O/P Voltage/Frequen cy, Load level, Battery voltage &level, T em perature, Model
Norm al(Green), W arning (Am ber), F ault (Red)
Beeping every 4 seconds
Beeping every second
Beeping continuou sly
85Vac ~ 150Vac or 170Vac ~ 300Vac
45Hz ~ 70Hz Auto-sensing
Voltage Regula tion
Frequen cy Regula tion
Overload Protection
Short Circuit Protection
Safety Standard
EMC
Marks
Multi-Interfaces Card(O ption)
LED
IEC Outlets
(220/230/240Vac)
Cold Start
W ave Form
EN62040 -1-1
EN62040 -2
CE
6
150Vac ± 2% ; 300Vac ± 2%
145Vac ± 2% ; 290Vac ± 2%
110/115/120Vac or 220/230/240Vac re-settable via LCD panel
± 15%
< 3% RMS for entire battery voltage range
4
3
Tower
Voltage Range
NEMA O utlets
3
4
Dim ensions(W *H*D )m m
Net W eigh t (K g)
Audible Noise(At 1M)
145*215*431
Operation Tem perature
Relative Hum idity
Recharging Current
Type
Quantity
Backup Tim e
Typical
Voltage
< 4 m s
(110/115/120Vac)
Rack
Tower & Rack convertible
110/115/120 Vac or 220/230/240Vac
Battery Mode
Low Battery
LCD Display
50Hz or 60Hz ± 0.1Hz
0.625
132Vac ± 2% ; 264.5Vac ± 2%
127Vac ± 2% ; 254.5Vac ± 2%
85Vac ± 2% ; 170Vac ± 2%
90Vac ± 2% ; 180Vac ± 2%
Synchronize to AC m ain
Mode Type
Rack Battery Bank APA BTR16:for 16 pcs 12V/7Ah or 16pcs 12V/9Ah.Dimension:W*H*D=440*132*465mm
7.5-10kVA connect to an external battery bank
All specifications mentioned above are subject to change without prior notice
Input
Output
DC Start
Transfer time
Battery
Control panel
Audible alarm
Communication interfaces
Environment
Physical
Safety conformance
Efficiency
Power Factor
Pure sine wave
> 80%
Voltage
Nom inal Voltage
< 55dBA
440*44*515
UPS Fault
Standard
Overload
Summary of Contents for APA-103T
Page 9: ...8 4 OUTLINE 4 1 Description 650VA Tower Case...
Page 10: ...9 1KVA 1 5K 2KVA Tower Case...
Page 11: ...10 1KVA 1 5KVA 2VA Rack Tower Convertible Case...
Page 12: ...11 3KVA Rack Tower Convertible Case...
Page 13: ...12 5KVA Rack Tower Convertible Case...
Page 14: ...13 7 5KVA 10KVA Rack Tower Convertible Case...
Page 15: ...14 1KVA 1 5KVA Rack 1U Case...
Page 26: ...25 1 Rated Spec Menu 2 Status Menu 3 Voltage Menu 4 Frequency Menu...
Page 27: ...26 5 Battery Status Menu 6 Output Power Menu 7 Temperature Menu 8 History Record Menu...