1. INTRODUCTION
Thank you for choosing PowerShield. This PowerShield
SAFEGUARD UPS is designed to provide safe and reliable
usage with minimal maintenance. Before you start please
read this manual. It contains instructions relating to safety,
installation, operation, maintenance and warranty of this
UPS. Please keep this manual in a safe place for future
use.
2. SAFETY INSTRUCTION
This section contains important safety instructions that
should be followed during usage of Power Shield product.
Changes and modification to any this unit not expressly
approved by Power Shield will void the product warranty.
ATTENTION: Electrical Safety
Maintenance must be performed by qualified
personnel. Failure to do so could result in an electric
shock.
Replace battery only with Power Shield supplied
battery.
Although the product may be unplugged from mains,
hazardous voltage still may be present through the
battery.
High current through conductive materials could
cause severe burns.
Check that the input power cord, output receptacles
are in good condition.
In order to maintain compliance with the EMC
directive, output cords attached to the UPS should not
exceed 10 meters in length.
Total leakage current from connected equipment and
the UPS must not exceeded 3.5mA for a pluggable
A type UPS.
CAUTION: Battery Safety
When replacing the batteries, use the same number
and type of batteries. See www.powershield.com.au
Do not dispose of batteries in a fire. The battery may
explode. Do not open or mutilate the battery.
Released electrolyte is harmful to the skin and eyes.
A battery can present a risk of electric shock and high
short circuit current. The following precaution should
be observed before replacing batteries
This unit contains no serviceable components other
than battery. Repairing of the product must only be
performed by qualified service personnel.
PowerShield
SAFEGUARD ( PSG750 )
User’s manual
.
3. PACKAGE CONTENTS
You should have received the following items inside of
package:
-
PowerShield SAFEGUARD 750VA UPS
-
PowerShield User’s Manual
-
Communication / USB cable
-
SAFEGUARD Veiwer CD monitoring software
Note: Before installation, please inspect the unit and make
sure that no damages have occurred during transit. If any
damage is found, please notify your dealer. Please keep
the shipping materials in the event the product must be
returned to a repair centre for service.
4. PRODUCT OVERVIEW
SAFEGUARD will protect your telephone system, PC and
other electronic devices from various power quality issues
including power loss. This UPS features three LED
indicators to display the status of UPS.
TOPVIEW
○
○
○
○
1
UPS & SURGE PROTECTION (x3) – These outlets
will provide power while mains power is present and
the UPS is “ON”. It will also provide power for a
limited time from the internal battery when the mains
fail.
○
○
○
○
1
FULL TIME SURGE PROTECTION (x3) – These
outlets do not provide any backup power when mains
fail. They do however provide continuous protection
against surges and the like and are perfect for
peripherals that do not need battery backup
○
○
○
○
2
Status indicators (See 7. STATUS INDICATOR
AND BEEPER section)
SIDE VIEW
3.
AC input Cord
4.
Input circuit
breaker (10 Amp)
5.
RJ45–modem/
phone/ network
Protection
6.
ON/OFF Switch
7.
USB interface port
5. GETTING STARTED
Placement
Avoid placing SAFEGUARD in
CONNECT EQUIPMENT & INITIAL STARTUP
CONNECTING MODEM/PHONE/NETWORK
Connect a single modem/phone/network line into surge
protected “ IN” connector on the back panel of the unit.
Connect from “OUT” connector to the computer with
telephone line cable.
CONNECTING USB COMMUNICATION CABLE
To allow for unattended OS shutdown, start up and status
montoring, connect the USB communication cable at one
end to the UPS and the other end to the PC.
COLD START FUNCTION
When the UPS is “OFF” and there is no utility power, it is still
possible to cold start the UPS to power the loads providing
your battery has sufficient charge.
WALL MOUNT of UPS
SAFEGUARD can be mounted to a wall surface. Use
template provided on your product box flaps as a template
to position the mounting fastener (not supplied).
Wall mount this product as follows:
1. Cut the template from your product box and hold the
cardboard template against the wall in the desired
location.
2. Use thumbtack or tape to secure the template against
the wall. Use pin to puncture the centre of each circle to
mark the wall.
3. Install the mounting fastener at marked location. Leave
the head of both fasteners 8mm out from the wall. The
fastener must be able to support 7.0kg.
4. Mounting the unit by positioning the keyhole slots over
the mounting fastener heads.
6. SOFTWARE INSTALLATION
1. Insert the SAFEGUARD Viewer CD into CD-ROM drive
and then follow the on-screen instructions. If there no
screen shows when inserting the CD after 1 minute,
please execute setup.exe for initiating installation
software.
2. Follow the on-screen instructions to install the software.
3. When your computer restarts, the monitoring software
will appear as an orange plug icon located in the system
tray, near the clock.
Plug the AC input cord into the
wall outlet. Turn on the UPS by
pressing the “ON/OFF” button
on the UPS. For the best
results, charge the battery for at
least 4 hours before initial use.
Once UPS is fully charged, you may now
proceed to connect equipment
UPS & SURGE PROTECTION (x3)
Only devices that require battery backup
such as PCs should be plugged into
these outlets
FULL TIME SURGE PROTECTION (x3)
Devices like printers that do not require
battery backup should be plugged into
these outlets. These devices will be
protected against surges and spikes
CAUTION: NEVER connect a laser printer
or scanner to the “UPS & SURGE
PROTECTION” outlets. This may cause
damage to the unit.