® Copyright ATH-Heinl GmbH & Co. KG, 2019, All rights reserved / Misprints and technical changes reserved / As of: 2019-03
Manufacturer ATH-Heinl GmbH & CO.KG
- 31 -
2.9.8.
System settings
The basic settings can be established using the system settings.
Display unit for the imbalance grams / ounces
+
Automatic start when closing the wheel protector on/off
+
Calibration programme for the automatic gauge (2D)
+
Calibration programme for the automatic gauge (optional 3D)
+
Calibration programme
+
HID programme
+
2.9.9.
Calibrating the weight sensors
The machine
MUST
be calibrated after securing and at a minimum before the season or after a longer
period of use.
Clamp a wheel that has already been balanced (14 or 15”) and
enter the wheel values (see Usage, Point 4).
In order to access the calibration system, you must press the key
combination shown opposite:
1.
First the C button and then the T button
2.
The [CAL] – [CAL] displays will appear and the indicator lights
flash.
3.
Release the buttons only when the indicator light is steady.
+
The balancing process for the calibration starts when you press the
START button or close the wheel protector.
The display shown opposite appears after the balancing process.
Attach the calibration weight (100 g) to the inside of the wheel rim.
/