![ATH-Heinl M72Z User Manual Download Page 35](http://html1.mh-extra.com/html/ath-heinl/m72z/m72z_user-manual_2998296035.webp)
® Copyright by ATH-Heinl GmbH & Co. KG, 2019, All rights reserved / Misprint and technical changes reserved / Issue: 2019/02
- 35 -
CLEANING OF VALVE BLOCK
•
Disconnect the air lines (H) from the valve block
(V).
•
Clean the valve block (V) with compressed air,
possibly it must be changed.
•
Clean the silencer (S). If the silencer is
damaged, change it.
MOUNTING HEAD ADJUSTMENT
•
Loosen the locking screw (1) on the mounting
head.
•
By tightening respectively loosening of both
setscrews (2) the angle of the mounting head to
the rim can be adjusted. The bead guide (4)
overlap the rim flange thereby approx. 6
–
7
mm. The roller (3) is laying on the rim flange.
•
After the adjustment make sure that both
setscrews (2) and the locking screw (1) are
fastened again.
CONTROLLING AND REFILLING OF GEAR OIL
•
Turn the turntable into a position so that you
can reach the oil filler easily.
•
Remove now the oil filler cap (3).
•
Insert a flexible and transparent hose into the
opening until it reaches the bottom of the gear.
•
Keep now one end of the hose shut so that no
air can get in.
•
Now pull the hose out again. Thereby the oil
level must be minimum 25 mm.
•
If necessary, refill oil accordingly.
3
Summary of Contents for M72Z
Page 1: ...USER S MANUAL ATH M72Z...