Life cycle

4.1

Transportation

The device should be transported in the same way as new devices of this type. If the original box or another
protection (e.g. corks) is not available, it is necessary to secure the device against shocks, vibrations and

moisture on one's own, using other equivalent methods.

4.2

Installation

The Control Unit Module MOD CNV PK420 is designed for installation inside control cabinets on the DIN35
rail or inside a terminal box according to the installation position as shown in Figure 2,  The installation

place should be accessible only for authorized personnel and, as far as possible, access of third-party
persons must be prevented. Reasonable elevation of the installation place is recommended so that to

make the device easily accessible for maintenance and repair. Locations with excessive moisture should be
avoided. 
All wiring should be made with the use of YTKSY, OMY, LiYY or similar cables with sufficient cross-section of

cores see Table 5. Maximum runs for the cable sections to wire the PK420 converter to a Control Unit, with
consideration of cable core cross-section, a listed in Table 4.

Cable core cross-section (mm

2

)

Maximum runs of cable sections

1.0

400

1.5

600

Table 4: Maximum runs of cable sections

Schematic diagrams for interconnections between the signal converter module and other components of
the Gas Safety System are provided in Figure 4 and Attachment [2].

Figure 4:  Schmatic diagram of interconnections between the signal converter module (MOD CNV PK420)

and other components of the system
4.3

Commissioning

Upon completion of all wiring make sure that the device is in sound operating condition by tripping the

appropriate inputs: Warning, Alarm and Failure (See Table 2 for positions of input contacts).

s. 7|9

User Manual: POD-016-ENG R01

COM

NO

NC

ALARM

WARNING

Control Unit

Relays

Gas Detectors

+

AL

OS

P

Control Unit Module

MOD CNV PK420

Contact inputs

+

S

-

Discrete outputs 

4 – 20mA

R

OBC

=240 Ω V

cc

Actuating device driven

Transmission line to 

be monitored

COM

NO

NC

_______

FAILURE

COM

NO

NC

Summary of Contents for MOD CNV PK420

Page 1: ...POD 016 ENG R01 User Manual Control Unit Module MOD CNV PK420 Product code PW 048 A...

Page 2: ...ring Detection and Reduction of gas hazards We invite you to familiarize yourself with our offer on www atestgaz pl Atest Gaz A M Pachole sp j ul Spokojna 3 44 109 Gliwice Poland tel 48 32 238 87 94 f...

Page 3: ...guarded may need consideration of other requirements during the entire lifetime of the product How to use this manual The following symbols of optical indicators status are used throughout the documen...

Page 4: ...ication of output signals produced by the Signal Converter Module MOD CNV PK420 5 Table 3 Specification of the terminal block 6 Table 4 Maximum runs of cable sections 7 Table 5 Technical specification...

Page 5: ...her processing by a Central Control Unit e g EcoAlpa Alpa P17 MOD LED8 etc For normal operation of the unit the PK FAILURE output of a control device wired to the MOD CNV PK420 module must be inverted...

Page 6: ...rs in Section 5 AL Tripping line for the ALARM signal OS Tripping line for the WARNING signal P Tripping line for the OPERATION signal Plus pole for tripping signals 2 Output Output port Plus pole for...

Page 7: ...imilar cables with sufficient cross section of cores see Table 5 Maximum runs for the cable sections to wire the PK420 converter to a Control Unit with consideration of cable core cross section a list...

Page 8: ...f with other household waste Instead it is the user s responsibility to ensure disposal of waste equipment by handing it over to a designated collection point for the recycling of waste electrical and...

Page 9: ...ut the state with the higher priority is transferred Protection class III Dimension See Figure 2 Acceptable cables 1 1 5 mm2 Enclosure Self extinguishing PPO Weight 0 1 kg Mandatory periodic inspectio...

Page 10: ...he use of certain hazardous substances in electrical and electronic equipment EN 50581 2012 This declaration of conformity is issued under the sole responsibility of the manufacturer Purpose and scope...

Page 11: ...Gliwice Poland VAT No PL 9691433231 tel 48 32 238 87 94 fax 48 32 234 92 71 e mail contact atestgaz pl Appendix PU Z 077 ENG R01 s 1 1 Alpa MOD LED8 MOD CNV PK420 Channel 1 EcoAlpa Alpa P17 S Detector...

Page 12: ...chole sp j ul Spokojna 3 44 109 Gliwice Poland VAT No PL 9691433231 tel 48 32 238 87 94 fax 48 32 234 92 71 e mail contact atestgaz pl Appendix PU Z 109 ENG R01 s 1 1 Input Channel 1 EcoAlpa Alpa P17...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Reviews: