23 / 74
FG_F6_MODBUS_EN_01 / 2020-06-17
Word
Bit n°
Mask
D.A. address
Meaning
Menu
Hexa
Dec
Read
Write
2
16
0001
1
243B
643B
Calibration check.
+Funct
17
0002
2
2416
6416
Valve codes (output codes).
+Funct
18
0004
4
2421
6421
Sealed component (Leak unit always PA)
+Funct
19
0008
8
2422
6422
Stamping.
+Funct
20
0010
16
Reserved.
21
0020
32
2424
6424
N test.
+Funct
22
0040
64
Reserved.
23
0080
128
2426
6426
Sending cond.: pass part.
RS232
24
0100
256
2427
6427
Sending cond.: fail test part.
RS232
25
0200
512
2428
6428
Sending cond.: fail ref. part.
RS232
26
0400
1024
2429
6429
Sending cond.: alarm presence.
RS232
27
0800
2048
242A
642A
Sending cond.: pressure error.
RS232
28
1000
4096
242B
642B
Sending cond.: end of cycle.
RS232
29
2000
8192
242C
642C
Sending cond.: recoverable.
RS232
30
4000
16384
243C
643C
Sending cond.: calibration.
RS232
31
8000
32768
242D
642D
Frame content: time stamp.
RS232
3
32
0001
1
2412
6412
Frame content: name.
RS232
33
0002
2
242E
642E
Content of the frame: pressure.
RS232
34
0004
4
242F
642F
Security.
Conf
35
0008
8
2414
6414
External dump.
Conf
36
0010
16
2430
6430
Exportation.
RS232
37
0020
32
240F
640F
Automatic reset.
Conf
38
0040
64
Reserved.
39
0080
128
Reserved.
40
0100
256
Reserved.
41
0200
512
2407
6407
Temperature correction.
+Funct
42
0400
1024
243D
643D
Recovery or indirect test.
Conf
43
0800
2048
243E
643E
Parameters automatic setting.
Conf
44
1000
4096
Reserved.
45
2000
8192
2439
6439
Page feed.
RS232
46
4000
16384
2434
6434
Sign change.
+Funct
47
8000
32768
2440
6440
After sale service cycle.
+Funct