Quick start manual - F5800
MR-F5800C-U
Quick start manual
ATEQ F5800
Page 2/17
PREAMBLE
1. DEFINITION OF THE ATEQ F5800
The
ATEQ F5800
is a compact
air/air leak detector used to test the
air-tightness of parts. The method
used is based on the measurement
of a small variation or drop in
differential pressure between the test
and reference parts, when both are
filled to an identical pressure.
TEST
PART
REFERENCE
PART
DIFFERENTIAL
SENSOR
PIEZO
SENSOR
TEST
PRESSURE
2. MEASUREMENT CHARACTERISTICS
2.1. P
RESSURE DROP MEASUREMENT
RANGE
ACCURACY
RESOLUTION
Maximum
0 – 50 Pa
+/- (2,5% of the pr 1 Pa)
0,01 Pa
0 – 500 Pa
+/- (2,5% of the pr 1 Pa)
0,1 Pa
0 – 5000 Pa
+/- (2,5% of the pr 10 Pa)
1 Pa
2.2. T
EST PRESSURE MEASUREMENT
RANGE
ACCURACY
RESOLUTION
Maximum
F.S. = 75 mbar*
+/- (1,5% of the p 0,2 hPa)
0,1 % F.S.
F.S. < 0,3 bar
+/- (1,5% of the pr 1 hPa)
0,1 % F.S.
0,3
≤
F.S.
≤
1 bar
+/- (1,5% of the pr 3 hPa)
0,1 % F.S.
1 < F.S.
≤
5 bar
+/- (1,5% of the pr 7.5 hPa)
0,1 % F.S.
5 < F.S.
≤
10 bar
+/- (1,5% of the pr 15 hPa)
0,1 % F.S.
10 < F.S.
≤
20 bar
+/- (1,5% of the pr 30 hPa)
0,1 % F.S.
* Specific (relative)
F.S. = Full scale.