ATEN SXP-500 User Manual Download Page 8

Operation

When operating the SXP-500, please take note of the following:

1. Since the SXP-500 is a DCE device, the serial device it connects to

must be configured as a DTE device.

2. In DCE mode, the unit uses RTS/DTR (pins 6 and 8) handshaking.

When RTS/DTR is set High, the computer is allowed to transmit
data. When the unit is busy, it sets the RTS/DTR line to Low, and
the computer stops transmitting data. Consequently, if the computer
can not identify the RTS/DTR signal, it may result in data loss.

3. The unit’s baud rate, data length, stop bits and parity settings must

be configured to match those of the computer.

4. You must reset the parallel printer before printing.

5. Make sure you have set the desired Conversion Direction (with DIP

switch 8).

Appendix

Specifications

Function

Specification

Power Consumption

AC 9V 50m A (max.)

Data Transmission Distance

Up to 5 m (30’)

Connectors

RS-232C

DB-9 female DCE

Centronics C-36 male

Interface Exchange

In

Serial or Parallel

Out

Parallel or Serial

Serial Communications Mode

DCE Only

LEDs

Green & Red

Microcontroller

ASIC

Temperature

Operating

50

0

 - 40

0

C

Storage

-20

0

-60

0

C

Humidity

0 -80%

Housing

Plastic

Weight

120 g

Dimensions

(L x W x H) 101 x 62 x 25.5 mm

- 7 -

2001 - 01 -10

Summary of Contents for SXP-500

Page 1: ...devices that connect to them This package contains M 1 Bidirectional Serial Parallel Converter SXP 500 M 1 User Manual If anything is damaged or missing contact your dealer Copyright 2000 ATEN Interna...

Page 2: ...rate is from 1200 to 115200 bps selectable by a combination of DIP Switch and Jumper settings The parallel interface speed is 92 16 KB sec The unit supports both hardware and software XON XOFF handsh...

Page 3: ...2 3 Baud rate Setting 4 Handshake Setting 5 Data and Stop Bits Setting 6 7 Parity Setting 8 Conversion Direction setting An explanation of each DIP Switch setting is given in the next section Note 1 W...

Page 4: ...2400 57600 ON OFF ON 9600 76800 ON OFF OFF 14400 115200 OFF ON ON 19200 153600 OFF ON OFF 38400 230400 OFF OFF ON 57600 460800 OFF OFF OFF 115200 921600 3 Handshake Segment Handshake 4 ON XON XOFF OFF...

Page 5: ...the SXP 500 into the PC s serial port 2 Plug the female end of a C 36 male female printer cable into the SXP 500 s printer connector 3 Plug the male end of the C 36 male female printer cable into the...

Page 6: ...er a Plug the D25 end of the cable into the PC s parallel port b Plug the C 36 end of the cable into the SXP 500 s Centronics connector 2 Use a serial cable with a male D9 connector at one end and a m...

Page 7: ...20 5 5 7 7 Cables a 25 pin 25 pin cable or a 9 pin 25 pin cable Tx Rx Rx Tx RTS CTS CTS RTS DSR DTR DTR DSR GND GND Device s Pin DB 25 C 36 1 1 2 9 2 9 10 10 11 11 12 12 13 13 14 14 15 32 16 31 17 36...

Page 8: ...nit s baud rate data length stop bits and parity settings must be configured to match those of the computer 4 You must reset the parallel printer before printing 5 Make sure you have set the desired C...

Page 9: ...2 TxD Transmit Data 3 RxD Receive Data 4 DSR Data Set Ready 5 GND Ground 6 DTR Data Terminal Ready 7 CTS Clear to Send 8 RTS Request to Send 9 RI Ring indicator Centronics Interface Timing Chart 8 DA...

Page 10: ...DATA BIT 4 6 DATA BIT 5 7 DATA BIT 6 8 DATA BIT 7 9 DATA BIT 8 10 ACK DATA RECEIVED ACKNOWLEDGE 11 BUSY DEVICE BUSY OR NOT 12 PAPER EMPTY PULL UP 13 SLCT PULL UP 14 A F PULL UP 15 N C 16 17 GROUND GR...

Page 11: ...Transmitting or Terminal device has not been set Ready for data transfer If powered Off turn the device On Otherwise reset the Transmitting or Terminal device Transmitting or Terminal device is in inc...

Page 12: ...nse will be required to take whatever measures may be required to correct the interference Limited Warranty IN NO EVENT SHALL THE DIRECT VENDOR S LIABILITY EXCEED THE PRICE PAID FOR THE PRODUCT FROM T...

Reviews: