DIP Switch Settings
Baud Rate:
The baud rate is set with DIP Switch segments 1 - 3 (located on the bottom
panel), and JP1 (located inside the housing), as shown in the table, below:
DIP Switch Segment
Baud Rate (bps)
1
2
3
JP1 Short
JP1 Open
ON
ON
ON
1200
38400
ON
ON
OFF
2400
57600
ON
OFF
ON
9600
76800
ON
OFF
OFF
14400
115200
OFF
ON
ON
19200
153600
OFF
ON
OFF
38400
230400
OFF
OFF
ON
57600
460800
OFF
OFF
OFF
115200
921600
- 3 -
Handshake:
Segment
Handshake
4
ON
XON / XOFF
OFF
Hardware
Data and Stop Bits:
Segment
Data Bits
Stop Bits
5
ON
7
2
OFF
8
1
Parity:
Segment
Parity
6
7
ON
Either
Parity Inhibit
OFF
ON
Even Parity
OFF
OFF
Odd Parity
Conversion Direction:
Segment
Direction
8
ON
Parallel to Serial
OFF
Serial to Parallel
2001 - 01 -10