System Functionality
387
© 2017, ATEÏS, member of PAX ProAV Group
To know a details of all the elements controlled by 3rd party devices, click [
window.
4.5.1.2
3rd Party Control List
Click [View > 3rd Party Control List] to open this window which lists all the elements available for 3rd
party control.
Devices Tab: Each tab will list all the elements controlled by a 3rd party device.
o
Item: Display the elements set for 3rd party control. The parent item shown as "single"
indicates the type is single. A single 3rd party control command can only control one
element.
o
Element: The name of the element.
o
Channel: The channel to which the element of component has belonged.
4.5.1.3
Machine Set Table
Function Name
Command Name
IN/reply Data Format
Ethernet MAC(Read Only)
M000
E1-00-00-AA-BB-A0
Ethernet IP
M001
192.168.100.254
Ethernet Sub Mask
M002
255.255.255.255
Ethernet Getway
M003
255.255.255.255
Ethernet DHCP flag(Read Only)
M004
0 or 1 (On/Off)
Ethernet Receive Port
M005
Example: 19720
Ethernet Send Port
M006
Example: 19721
4.5.1.4
Communication Protocol
Programmable RS232 settings:
Communication can be established using a standard-asynchronous-serial protocol. The UART settings
are shown as below.
Name
Setting
Baud rate
BR115200 /
BR57600 /
BR56000 /
BR38400 /
BR19200 /
BR9600 (def.) /
BR4800 /
BR2400 /
BR1200 /
BR600 /
Data bits
8
Parity
None /
Odd /
Even /
Stop bit
1