Atdec AWMS-2-BT75-G Installation Manual Download Page 2

AWMS-2-BT75-G Page 2 of 4

2. Attach grommet clamp on desk

Option A

 - Through grommet hole 

80mm (3

1

/8

”) max hole diameter

1. Assemble post to clamp plate 

1.1

Option B - 

As heavy duty bolt through

75mm

100mm

75mm

100mm

NOTE:

For 75mm VESA unscrew 
5mm to access top holes

Option A - 

Attach VESA 

plate with M4x10 screws.

Option B - 

For recessed 

VESA use 10mm spacers 
and M4x20 screws.

3.1

 VESA compatibility.

NOTE: 

 

Some displays require the use of 
a VESA adapter before attaching 
the VESA plate. This VESA adapter 
may ship in the box with the display. 
Consult your display’s installation 
guide for further information.

3. Attach VESA plates to displays

D

J

TOP

D

K

L

I

A

M

B

E

A

B

G

F

N

9mm

(

3

/

’’)

60mm (2

”)

minimum

G

F

N

Installed position