ATC Sun Ray RF 1000w Operating And Installation Instructions Download Page 18

18

DEFAULT VALUES

Default mode: OFF

Type of control: PID

Temperature offset: 0ºC

Open window detection: disabled

Autoadaptive: disabled

Programming in one hour intervals, all hours in antifrost mode

Setpoint temperatures:

Anti-freeze 7ºC

Eco 18ºC

Comfort 21ºC

Manual temperature: 21ºC

Boost mode temperature: 21ºC

Boost mode time: 1h

Low Surface Temperature: disabled

Password status: activated

Password: 0000

Units: ºC

Keyboard: unlocked

Easy mode: disabled

Runback mode: disabled

Setback: disabled

Runback temperatures:

Antifreeze: 7ºC

Eco: 18ºC

Comfort: 21ºC 

Max. Temperature of Runback: 21ºC

Max time of Runback: 30min

Screen brightness on: max (4)

Screen brightness on: min (OFF)

Screen time on: min (5s)

Beep: disabled

EcoDisplay: disabled

DST: enabled

Default date: 01-01-2019 (Tuesday)

Summary of Contents for Sun Ray RF 1000w

Page 1: ...n Ray RF 350w Sun Ray RF 500w Sun Ray RF 750w Sun Ray RF 1000w Sun Ray RF 1250w Sun Ray RF 1500w Sun Ray RF 1800w NOTE A qualified electrician must carry out the electrical installation of this radiat...

Page 2: ...INSTRUCTIONS 8 Manual Programming 9 Set program temperatures 9 Setting the time and date 9 Entering a program 10 Boost 11 Display settings 11 Programming with APP 12 Keypad Locking Anti Tamper 12 Adva...

Page 3: ...cturer or ATC ATC should be contacted in case of any oil leakage A Fused Spur must be included in the wiring to the radiator This appliance can be used by children aged 8 years and above and persons w...

Page 4: ...e of heat radiation the air circulation channels provide a very efficient convection effect A unique manufacturing process provides bubble free filling so that the fluid delivers warmth from the heati...

Page 5: ...ted to the power supply by means of an all pole circuit breaker with a contact gap of at least 3mm or by a thermal magnetic circuit breaker LOCATION The ideal place to position the Sun Ray RF radiator...

Page 6: ...between the second and third elements from each end Fig 1 Fig 2a Fig 3a Fig 2b Fig 3b Place the supports between the elements as shown in Figure 2a mark points on the walls through the fixing holes as...

Page 7: ...y RF is designed to be used in conjunction with the SunRay Smart Gateway system and App providing total control of your radiators from anywhere in the world via the internet The App is available for b...

Page 8: ...diator The TFT screen will turn blank and the radiator will lose any connection with the SunRayRF Gateway Stand by function From any on screen press the Mode OK button until the symbol is present as s...

Page 9: ...ect SETTINGS and the press OK In the TIME menu the Time Date and Daylight Savings DST can be set MANUAL PROGRAMMING SETTING THE TIME AND DATE To assist with programming the TFT screen is backlit and w...

Page 10: ...button until the CONFIG menu appears then use the buttons to select PROGRAM and press OK ENTERING A PROGRAM To enter a program into the radiator first select the day of the week in the upper left corn...

Page 11: ...g screen will be displayed adjust the time required between 1 hour and 24hours To return to the boost screen press CONFIG To return to normal operation from the Boost mode Press the OK button The Disp...

Page 12: ...ult See Password Settings Chapter for further details on changing passwords To Lock the radiator Press and hold the and buttons until the lock screen appears Enter the password on the screen and press...

Page 13: ...the room is at the correct temperature at the programmed starting time The Low Surface Temperature LST menu will allow the output of the heater to be limited to a lower setting to prevent the surface...

Page 14: ...d and press OK RUNBACK MODE The Sunray RF Heater comes with a runback mode for use when the heater will be installed in areas where restricted user control is required When Runback Mode is active it a...

Page 15: ...Please note that the Runback temperature cannot be set higher than the Comfort setting in the main menu SETBACK The setback mode can be used to limit the temperature that the area where the heater is...

Page 16: ...inimum and the Max temp setting as a maximum The Radiator will always come on at the Runback set point In the example above the user has activated runback and then increased the temperature to the Max...

Page 17: ...r reconnects to the gateway When a radiator has been paired with a Gateway the text Link and an antenna with flashing waves appears on the top right of the screen When the Gateway is not powered or it...

Page 18: ...Boost mode temperature 21 C Boost mode time 1h Low Surface Temperature disabled Password status activated Password 0000 Units C Keyboard unlocked Easy mode disabled Runback mode disabled Setback disa...

Page 19: ...W At minimum heat output elmin 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW In standby mode elSB 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW Type of...

Page 20: ...op for inspection to establish whether the fault is covered under the guarantee The guarantee is valid in the UK and Ireland only This guarantee is additional to your statutory rights In the unlikely...