13
OFF
ON
Open Window
OK
21
.5°C
Set point:
Tue. 11:00
OFF
ON
Self Adaptive
OK
OFF
ON
EASY mode
OK
OFF (100%)
75%
50%
23%
LowSurfaceTemp
OK
COMFORT
21
.5°C
Set point:
Tue. 15:00
21
.5°C
Set point:
EASY
set temp
Status ON
Change
Password
OK
Runback
Setback
Max. Temp.
Runback
OK
Confirm
OK CANCEL
RESET
OK
21
.5°C
Set point:
LST 23%
Tue. 11:00
The Open window setting will
turn the heating of the radiator off
if the unit detects a rapid drop in
temperature over a short period
of time.
To reactivate the heating once
the open window function has
activated press any button the
radiator. If the temperature rises
above the minimum detected
temperature then the heater
will reactivate and turn the open
window function off.
If this function comes on
frequently e.g. in an area where
there is an external doorway, it is
recommended to turn the open
window function off.
The Self Adaptive setting will
allow the radiator to calculate the
optimum time to start the heating
cycle when running in Program
mode.
If this setting is turned on it will
be shown in the Notification area
and the heating will come on prior
to the programmed starting time
so that the room is at the correct
temperature at the programmed
starting time.
The Low Surface Temperature
(LST) menu will allow the output
of the heater to be limited to a
lower setting to prevent the
surface of the heater becoming
too hot. If a surface temperature
of less than 43°C is required use
the lowest setting.
It is recommended that if the
LST function is activated then
the radiator should be locked
with a non standard password
after activation.
(See Password Section)
EASY Mode is a simple mode
of operation where by only the
+ and – buttons on the radiator
operate to increase or decrease
the temperature. The OK button
is deactivated. To turn the
radiator on or off use the Main
power button on the side of the
heater.
When running in Easy mode
the Screen will show EASY in
the notification area to let the use
know that the mode is active.
To exit EASY mode press and
hold the CONFIG button for 10
seconds, then select “off”.
Runback:
See
Runback
Section on page
Password: See Password
Section on page
Resetting the radiator will
return all settings to the factory
defaults and will also delete
any ‘pairing’ with a Sun Ray RF
Gateway.
To activate the RESET feature
select with arrow buttons OK,
and press the OK button.
The first press of any button will wake up the radiator any
further button presses will activate the function required.