ATC Sun Ray RF 1000w Operating And Installation Instructions Download Page 13

13

OFF

ON

Open Window

OK

21

.5°C

Set point:

Tue. 11:00

OFF

ON

Self Adaptive

OK

OFF

ON

EASY mode

OK

OFF (100%)

75%

50%

23%

LowSurfaceTemp

OK

COMFORT

21

.5°C

Set point:

Tue. 15:00

21

.5°C

Set point:

EASY

set temp

Status      ON

Change

Password

OK

Runback

Setback

Max. Temp.

Runback

OK

Confirm

OK  CANCEL

RESET

OK

21

.5°C

Set point:

LST 23%

Tue. 11:00

The  Open  window  setting  will 

turn the heating of the radiator off 

if the unit detects a rapid drop in 

temperature over a short period 

of time. 

To reactivate  the  heating once 

the  open  window  function  has 

activated press any button the 

radiator. If the temperature rises 

above  the  minimum  detected 

temperature  then  the  heater 

will reactivate and turn the open 

window function off.

If  this  function  comes  on 

frequently e.g. in an area where 

there is an external doorway, it is 

recommended  to  turn  the  open 

window function off. 

The  Self  Adaptive  setting  will 

allow the radiator to calculate the 

optimum time to start the heating 

cycle  when  running  in  Program 

mode. 

If this setting is turned on it will 

be shown in the Notification area 

and the heating will come on prior 

to the programmed starting time 

so that the room is at the correct 

temperature at the programmed 

starting time.

The Low Surface Temperature 

(LST) menu will allow the output 

of  the  heater  to  be  limited  to  a 

lower  setting  to  prevent  the 

surface  of  the  heater  becoming 

too hot. If a surface temperature 

of less than 43°C is required use 

the lowest setting.

It  is  recommended  that  if  the 

LST function is activated then 

the  radiator  should  be  locked 

with  a  non  standard  password 

after activation.

(See Password Section)

EASY Mode is a simple mode 

of  operation  where  by  only  the 

+ and – buttons on the radiator 

operate to increase or decrease 

the temperature. The OK button 

is  deactivated.  To  turn  the 

radiator on or off use the Main 

power button on the side of the 

heater. 

When  running  in  Easy  mode 

the  Screen  will  show  EASY  in 

the notification area to let the use 

know that the mode is active. 

To exit EASY mode press and 

hold the CONFIG button for 10 

seconds, then select “off”.

Runback: 

See 

Runback 

Section on page 

Password:  See  Password 

Section on page

Resetting  the  radiator    will  

return  all  settings  to the factory 

defaults  and  will  also  delete 

any ‘pairing’ with a Sun Ray RF 

Gateway.

To  activate  the RESET feature 

select  with  arrow  buttons  OK, 

and press the OK button.

 The first press of any button will wake up the radiator any 

further button presses will activate the function required. 

Summary of Contents for Sun Ray RF 1000w

Page 1: ...n Ray RF 350w Sun Ray RF 500w Sun Ray RF 750w Sun Ray RF 1000w Sun Ray RF 1250w Sun Ray RF 1500w Sun Ray RF 1800w NOTE A qualified electrician must carry out the electrical installation of this radiat...

Page 2: ...INSTRUCTIONS 8 Manual Programming 9 Set program temperatures 9 Setting the time and date 9 Entering a program 10 Boost 11 Display settings 11 Programming with APP 12 Keypad Locking Anti Tamper 12 Adva...

Page 3: ...cturer or ATC ATC should be contacted in case of any oil leakage A Fused Spur must be included in the wiring to the radiator This appliance can be used by children aged 8 years and above and persons w...

Page 4: ...e of heat radiation the air circulation channels provide a very efficient convection effect A unique manufacturing process provides bubble free filling so that the fluid delivers warmth from the heati...

Page 5: ...ted to the power supply by means of an all pole circuit breaker with a contact gap of at least 3mm or by a thermal magnetic circuit breaker LOCATION The ideal place to position the Sun Ray RF radiator...

Page 6: ...between the second and third elements from each end Fig 1 Fig 2a Fig 3a Fig 2b Fig 3b Place the supports between the elements as shown in Figure 2a mark points on the walls through the fixing holes as...

Page 7: ...y RF is designed to be used in conjunction with the SunRay Smart Gateway system and App providing total control of your radiators from anywhere in the world via the internet The App is available for b...

Page 8: ...diator The TFT screen will turn blank and the radiator will lose any connection with the SunRayRF Gateway Stand by function From any on screen press the Mode OK button until the symbol is present as s...

Page 9: ...ect SETTINGS and the press OK In the TIME menu the Time Date and Daylight Savings DST can be set MANUAL PROGRAMMING SETTING THE TIME AND DATE To assist with programming the TFT screen is backlit and w...

Page 10: ...button until the CONFIG menu appears then use the buttons to select PROGRAM and press OK ENTERING A PROGRAM To enter a program into the radiator first select the day of the week in the upper left corn...

Page 11: ...g screen will be displayed adjust the time required between 1 hour and 24hours To return to the boost screen press CONFIG To return to normal operation from the Boost mode Press the OK button The Disp...

Page 12: ...ult See Password Settings Chapter for further details on changing passwords To Lock the radiator Press and hold the and buttons until the lock screen appears Enter the password on the screen and press...

Page 13: ...the room is at the correct temperature at the programmed starting time The Low Surface Temperature LST menu will allow the output of the heater to be limited to a lower setting to prevent the surface...

Page 14: ...d and press OK RUNBACK MODE The Sunray RF Heater comes with a runback mode for use when the heater will be installed in areas where restricted user control is required When Runback Mode is active it a...

Page 15: ...Please note that the Runback temperature cannot be set higher than the Comfort setting in the main menu SETBACK The setback mode can be used to limit the temperature that the area where the heater is...

Page 16: ...inimum and the Max temp setting as a maximum The Radiator will always come on at the Runback set point In the example above the user has activated runback and then increased the temperature to the Max...

Page 17: ...r reconnects to the gateway When a radiator has been paired with a Gateway the text Link and an antenna with flashing waves appears on the top right of the screen When the Gateway is not powered or it...

Page 18: ...Boost mode temperature 21 C Boost mode time 1h Low Surface Temperature disabled Password status activated Password 0000 Units C Keyboard unlocked Easy mode disabled Runback mode disabled Setback disa...

Page 19: ...W At minimum heat output elmin 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW In standby mode elSB 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW Type of...

Page 20: ...op for inspection to establish whether the fault is covered under the guarantee The guarantee is valid in the UK and Ireland only This guarantee is additional to your statutory rights In the unlikely...

Reviews: